7-2-6 SWITCH INPUT CIRCUIT
* The circuit shown below is the input circuit to detect the signals of the test S/W for checking the refrigerator.
7-2-7 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING COMPENSATION CIRCUIT
1. The circuits for less cooling and overcooling compensation in a refrigerator compartment
¥ The above OPTION circuit is to compensate refrigerator temperature by simply cutting during service.
- 29 -
OVER COOLING
LESS COOLING
COMPENSATION
COMPENSATION
REFRIGERATOR TEMPERATURE
REMARKS
JCR1
JCR2
JCR3
JCR4
COMPENSATION VALUES
CUT
+1¡C
CUT
CUT
+2¡C
CUT
-1¡C
CUT
CUT
-2¡C
CUT
CUT
0¡C
CUT
CUT
0¡C
CUT
CUT
CUT
+1¡C
CUT
CUT
CUT
-1¡C
0¡C(AT FACTORY)