- 14 -
6-3 ANOTHER ELECTRIC COMPONENTS
t
Cooling is impossible
Compressor
doesn’t run.
Running state of
Compressor is poor.
Check a starting
voltage.
Check if current flows to
the following
components.
a. Thermistor
b. Starting devices
c. OLP
d. Compressor coil
e. Circuit Parts
Low voltage.
Poor contacting.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of motor
Compressor.
Replace
the compressor.
Replace
each component.
Raise the voltage.
Replace
each component.
Cause.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
t
Cooling ability is poor
Fan motor
doesn’t run.
Much frost are sticked
to the EVAPORATOR.
Poor contacting.
Coil is shorted.
Shorted.
Replace
each component.
Replace
each component.
Replace
each component.
Check current flowing
in door S/W.
Check current flowing
in the Fan Motor.
Check current flowing
of the following
components.
¥ Def. Sensor
¥ FUSE-M
Check current flowing
of the following
components.
¥ Heater plate
¥ Heater cord
Summary of Contents for GR-B492Y*C
Page 35: ...7 5 2 REPLACEMENT PARTS LIST 35 ...
Page 36: ... 36 ...
Page 37: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 37 ...
Page 38: ... 38 7 5 4 PWB ASS Y DISPLAY I MICOM AND PARTS LIST ...
Page 39: ... 39 7 5 5 V LED DISPLAY PART LIST ...
Page 40: ...7 6 PWB DIAGRAM 40 ...
Page 41: ... 41 ...
Page 43: ... 43 111 138 154A 140A 120 110 134 149B 118 119 405C 404A 405C 405A 329B 155J ...
Page 44: ... 44 241D 244C 244A 241A 235A 173 241C 205A 205A 279A 162 212A 212C 101 102 122 123 241E 172 ...