7-2-6 SWITCH INPUT CIRCUIT
* The circuit shown below is the input circuit to detect the signals of the test S/W for checking the refrigerator.
7-2-7 TEMPERATURE COMPENSATION & OVERCOOLING/UNDERCOOLING COMPENSATION CIRCUIT
1. The circuits for less cooling and overcooling compensation in a refrigerator compartment
• The above OPTION circuit is to compensate refrigerator temperature by simply cutting during service.
- 28 -
CUT
OVER COOLING
LESS COOLING
COMPENSATION
COMPENSATION
REFRIGERATOR TEMPERATURE
REMARKS
JCR1
JCR2
JCR3
JCR4
COMPENSATION VALUES
CUT
+1°C
CUT
CUT
+2°C
CUT
-1°C
CUT
CUT
-2°C
CUT
CUT
0°C
CUT
CUT
0°C
CUT
CUT
CUT
+1°C
CUT
CUT
CUT
-1°C
0°C(AT FACTORY)