7-2 PCB FUNCTION
7-2-1 POWER CIRCUIT
TRANS 2nd part
Ⓐ
is composed of the RELAY-operating POWER(12Vdc) and power (5Vdc) supplying POWER to MICOM
and IC.
TRANS 2nd part
Ⓑ
is composed of the CIRCUIT supplying POWER(12Vdc) to DISPENSER PUMP MOTOR.
Voltage of each part is as follows.
VA1 is a part preventing from over-voltage and noise.
- 23 -
PART
Ⓐ
PART
both ends of VA1
both ends of CE1
both ends of CE2
both ends of CC2
VOLTAGE
220 Vac
17 Vdc
12 Vdc
5 Vdc
PART
Ⓑ
PART
both ends of 2nd part
both ends of CE6
both ends of CE7
VOLTAGE
13 Vdc
15 Vdc
12 Vdc
Summary of Contents for GR-642APA
Page 34: ...7 5 MAIN PWB ASS Y AND PARTS LIST 7 5 1 MAIN PWB ASS Y 34 ...
Page 35: ...7 5 2 REPLACEMENT PARTS LIST 35 ...
Page 36: ...7 5 3 PWB ASS Y DISPLAY AND PARTS LIST 36 ...
Page 37: ...7 6 PWB DIAGRAM 37 ...
Page 38: ... 38 ...