D. PCB ASSEMBLY REMOVAL
1) Remove the control panel assembly from the
cavity. (Refer to control panel assembly removal
on previous page.)
2) Remove screws which hold the PCB SUB ASSÕY to
the control panel.
3) Disconnect the flat cable from the PCB SUB
ASSÕY and take off the PCB SUB ASSÕY
E. DOOR MAIN ASSEMBLY REMOVAL
1) Open the door.
2) Remove the choke cover very carefully with a flat-blade
screwdriver.
CAUTION: Be careful not to damage door seal plate
by screwdriver.
3) Lift up and push the door.
NOTE:
1. After replacing the door, be sure to check that the
primary switch, monitor switch, and secondary switch
operate normally.
2. After replacing the door, check for microwave energy
leakage with a survey meter. Microwave energy must
be below the limit of 4 mW/cm. (with a 275 ml water
load)
3. When mounting the door assembly to the oven
assembly, be sure to adjust the door assembly parallel
to the chassis. Also adjust so the door has no play
between the inner door surface and oven frame
assembly. If the door assembly is not mounted
properly, microwaves may leak from the clearance
between the door and the oven.
5-4
Door seal plate
Control Panel
Key Membrane
PCB Sub Asm
Remove door
Remove choke cover
Spacer
Summary of Contents for GoldStar MS-113YE
Page 27: ...6 2 13552A 13213A 13352A 13581A 13720D 13806D 14970A 14026A 15006A 13536A DOOR PARTS ...
Page 28: ...6 3 24781M 26638A 23572A 268711 WTP018 CONTROLLER PARTS ...
Page 29: ...6 4 33052M 340511 36549S WTP013 33390G WTT010 WSZ185 33112U 35889A OVEN CAVITY PARTS ...
Page 30: ...6 5 43501A WSZ085 466002 466003 466001 43500A LATCH BOARD PARTS ...
Page 32: ...6 7 63303L 56170D 63303R WSZ002 WTT021 WTT028 647781 BASE PLATE PARTS ...
Page 33: ...8 1 SCHEMATIC DIAGRAM OF P C B ...
Page 34: ...8 2 PRINTED CIRCUIT BOARD ...