5-8
COMPONENT TEST PROCEDURE
CAUTIONS
1. DISCONNECT THE POWER SUPPLY CORD FROM THE OUTLET WHENEVER REMOVING THE
OUTER CASE FROM THE UNIT. PROCEED WITH THE TEST ONLY AFTER DISCHARGING THE HIGH
VOLTAGE CAPACITOR AND REMOVING THE WIRE LEADS FROM THE PRIMARY WINDING OF THE
HIGH VOLTAGE TRANSFORMER. (SEE PAGE 2-1)
2. ALL OPERATIONAL CHECKS WITH MICROWAVE ENERGY MUST BE DONE WITH A LOAD (1 LITER
OF WATER IN CONTAINER) IN THE OVEN.
HIGH VOLTAGE
TRANSFORMER
(Wire leads removed)
MAGNETRON
(Wire leads removed)
Approx.: 0.3 ~ 0.8 ohm
Approx.: 100 ~ 200 ohm
Less than: 1 ohm
Normal: Infinite
Normal: Infinite
Normal: Less than 1 ohm
Normal: Infinite
PRIMARY
TERMINAL
SECONDARY
TERMINAL
FILAMENT
WINDING
TERMINAL
COMPONENTS TEST
PROCEDURE RESULTS
1. Measure the resistance.
(Ohm-meter scale: Rx1 and Rx100)
• Primary winding
• Secondary winding
• Filament winding
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Primary winding to ground
• Filament winding to ground
1. Measure the resistance.
(Ohm-meter scale: Rx1)
• Filament terminal
2. Measure the resistance.
(Ohm-meter scale: Rx1000)
• Filament to chassis
Summary of Contents for GoldStar MAB745B
Page 9: ...SCHEMATIC DIAGRAM I Check the Rating Model No 4 3 ...
Page 10: ...SCHEMATIC DIAGRAM II Check the Rating Model No ADD Noise filter 4 4 ...
Page 28: ...6 2 DOOR PARTS 13581A 14970A 14026A 13552A 13213A 13352A 13720D 13536A EV ...
Page 29: ...6 3 CONTROLLER PARTS 23506A 23572A 268711 WTT028 24781M EV ...
Page 31: ...6 5 LATCH BOARD PARTS 466001 466003 WSZ085 466001 43500A 56912B 55262A EV ...
Page 34: ...6 8 BASE PLATE PARTS 56170D 63302A 63303A WTT021 WSZ002 65006B 65006B EV ...
Page 35: ......