MEASUREMENT WITH OUTER CASE
REMOVED
• When you replace the magnetron, measure for
microwave energy leakage before the outer case is
installed and after all necessary components are
replaced or adjusted.
Special care should be taken in measuring the
following parts. (Circled area of Fig. below)
- Around the magnetron
- The waveguide
MEASUREMENT WITH A FULLY
ASSEMBLED OVEN
• After all components, including the outer case, are fully
assembled, measure for microwave energy leakage
around the door viewing window, the exhaust opening,
and air inlet openings.
• Microwave energy leakage must not exceed the values
prescribed below.
NOTE
: Leakage with the outer case removedless than
5 mW/cm.sq. Leakage for a fully assembled
oven (Before the latch switch (primary) is
interrupted) with the door in a slightly opened
position-less than 2 mW/cm.sq.
NOTES WHEN MEASURING
• Do not exceed meter full scale deflection.
• The test probe must be removed no faster than
1 inch/sec (2.5 cm/sec) along the shaded area,
otherwise a false reading may result.
• The test probe must be held with the grip portion of the
handle.
A false reading may result if the operator's hand is
befween the handle and the probe.
• When testing near a corner of the door, keep the probe
perpendicular to the surface making sure the probe
horizontally along the oven surface; this may possibly
cause probe damage.
RECORD KEEPING AND NOTIFICATION
AFTER MEASUREMENT
• After adjustment and repair of any microwave energy
interruption or microwave energy blocking device,
record the measured values for future reference. Also
enter the information on the service invoice.
• The microwave energy leakage should not be more
than 4 mW/cm.sq. after determining that all parts are in
good condition, functioning properly and genuine
replacement parts which are listed in this manual have
been used.
• At least once a year, have the electromagnetic energy
leakage monitor checked for calibration by its
manufacturer.
5-2
WARNING : AVOID CONTACTING ANY
HIGH VOLTAGE PARTS
• When you remove the screws, using the
tamper-resistant Torx driver have a
pin-in-head.
SPECIAL TIP
• This oven used the button head screws.
Button Head
(Torx style 2)
Summary of Contents for GoldStar MAB745B
Page 9: ...SCHEMATIC DIAGRAM I Check the Rating Model No 4 3 ...
Page 10: ...SCHEMATIC DIAGRAM II Check the Rating Model No ADD Noise filter 4 4 ...
Page 28: ...6 2 DOOR PARTS 13581A 14970A 14026A 13552A 13213A 13352A 13720D 13536A EV ...
Page 29: ...6 3 CONTROLLER PARTS 23506A 23572A 268711 WTT028 24781M EV ...
Page 31: ...6 5 LATCH BOARD PARTS 466001 466003 WSZ085 466001 43500A 56912B 55262A EV ...
Page 34: ...6 8 BASE PLATE PARTS 56170D 63302A 63303A WTT021 WSZ002 65006B 65006B EV ...
Page 35: ......