36
PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
Checking point
Display
None
LqC 1
1 time
■
COIN/CARD TYPE
- ELECTRIC TYPE : US:OE
- GAS TYPE : US:Og
■
OPL TYPE
- ELECTRIC TYPE : CA:PE
- GAS TYPE : CA:Pg
Version and code of machine (All LED on) CARD/COIN
machine - Display US:OE or US:Og and gU:XX
alternately. OPL machine – Display CA:PE or CA:Pg and
gU:XX alternately. XX is the version number
2 time
PDA CHECK
Ir--
3 time
Motor runs.
Measured moisture value (70~239)
4 time
■
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 (2700W)
■
GAS TYPE: GAS valve runs.
Motor + Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
5 time
■
ELECTRIC TYPE: Heater runs.
Motor + Heater 1 +Heater 2 (5400W)
■
GAS TYPE: GAS valve runs.
Motor+Valve
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
6 time
LED & KEY CHECK
Press High Temp. button.
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button.
Version and code of machine
7 time
Test ends.
LqC1
During check, if the
door is open.
Door switch
(Motor & Heater Off, Buzzer beeps
seven times)
dE
(The door is open. Please close the door completely)
During check, if the
door is closed
Test goes back at step 2.
(Motor on & Heater Off)
Measured moisture value (70~239)
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
NOTE