2-4. Ice Ejection Control Function
1. This is to eject ice from ice maker cube mould after ice making is completed.
2. If Hall IC signal is on within 3.6 seconds after ice ejection motor rotates in normal direction, it does not proceed ice
ejection but waits. If the ice bank is full, ice ejection motor rotates in normal direction in every hour to check the condition
of ice bank. If the ice bank is not full, the water supply control starts after completion of ice ejection control. If the ice bank
is full, ice ejection motor rotates in reverse direction and sops under ice making or waiting conditions.
3. If ice bank is not full, ice ejection starts. The cube mould tilts to the maximum and ice is separated from the mould and ice
checking lever raises.
4. Ice ejection motor stops for 1 second if Hall IC signal changes from OFF (low) to ON (high) after 3.6 seconds when ice
ejection motor rotates in normal direction. If there is no change in Hall IC signals within 1 minute after ice ejection motor
operates, ice ejection motor stops as ice ejection motor or hall IC is out of order.
5. If ice ejection motor or Hall IC is abnormal, ice ejection motor rotates in normal direction to exercise initial operation. It
resets the ice maker if ice ejection motor or Hall IC is normal.
6. The mould stops for 1 second at maximum tilted conditions.
7. The mould returns to horizontal conditions as ice ejection motor rotates in reverse direction.
8. When the mould becomes horizontal, the cycle starts to repeat:
Water Supply
→
Ice Making
→
Ice Ejection
→
Mould Returns to Horizontal
ICE MAKER AND DISPENSER WORKING PRINCIPLES AND REPAIR
- 88 -
Bank is
not full
HALL IC
OUTPUT
SIGNALS
Bank is
full
HALL IC
OUTPUT
SIGNALS
ICE CHECKING
AXIS
ICE CHECKING LEVEL 30°
Maximum tilting
point
Ice making
(Original point)
Lock
2±1 sec
9±3 sec
8±3 sec
Ice Checking
Ice Ejection
Lock
Horizontal
Conditions
Level Retrun
Conditions
<Timing Chart During Ice Ejection>
Summary of Contents for GC-L207TLQK.CGSQSTG
Page 23: ...EXPLATION FOR MICOM CIRCUIT 32 GC P L207 88 LED GC P L207 Bar LED GC P L207 Dot LED ...
Page 28: ...1 5 Temperature sensing circuit EXPLATION FOR MICOM CIRCUIT 28 GC L207 Bar LED F C A B D ...
Page 32: ...EXPLATION FOR MICOM CIRCUIT 50 GC P L207 Bar LED GC P L207 Dot LED b a e d b a e d ...
Page 38: ...EXPLATION FOR MICOM CIRCUIT 62 GC P L207 Bar LED ...
Page 39: ...EXPLATION FOR MICOM CIRCUIT 68 GC P L207 Bar LED ...
Page 40: ...EXPLATION FOR MICOM CIRCUIT 69 GC P L207 Bar LED ...
Page 41: ... GC P L207 Bar LED EXPLATION FOR MICOM CIRCUIT 78 ...
Page 42: ...EXPLATION FOR MICOM CIRCUIT 79 PWBASSEMBLY DISPLAY ...
Page 49: ...CIRCUIT 94 GC P L B C207 Bar LED The circuit has been only applied to voltage except 220v ...
Page 100: ......