Since door switch sensing switch (A), (B) are a separate switch even if the door switch of the freezing room normally
operates, they may fail to sense door opening in the failure of switch at both ends of (A) and (B) or in failure of the L/wire.
✽
Lamp does at the cold storage room not turn on if the door switch of the cold storage room fails to sense the door open
switch (c ), (d) or the home bar switch.
EXPLATION FOR MICOM CIRCUIT
- 41 -
Closing
5 V ( A - B , C - D . S/W at both ends are at Off status)
Opening
5 V ( A - B , C - D . S/W at both ends are at On status)
Measuring part
IC1 (MICOM) No. 47, 46 Pin
Door of Freezing/Cold Storage Room
CONDITIONS
Bell sounds when button on
Beep sounds when warning
MEASURING
dosplay is pressed.
door opening.
OFF
POINTS
IC1 (No. 48 Pin)
5 V
IC1 (No. 51 Pin)
0 V
0.05 s
2.63 kz (DING)
2.63 kz (BEEP)
OFF
2.21 kz (DONG)
0.2 s
0.1 s
0.4 s
0.5 s
0.5 s
5 V
0 V
5 V
0 V
5 V
0 V
5 V
0 V
Summary of Contents for GC-L207TLQK.CGSQSTG
Page 23: ...EXPLATION FOR MICOM CIRCUIT 32 GC P L207 88 LED GC P L207 Bar LED GC P L207 Dot LED ...
Page 28: ...1 5 Temperature sensing circuit EXPLATION FOR MICOM CIRCUIT 28 GC L207 Bar LED F C A B D ...
Page 32: ...EXPLATION FOR MICOM CIRCUIT 50 GC P L207 Bar LED GC P L207 Dot LED b a e d b a e d ...
Page 38: ...EXPLATION FOR MICOM CIRCUIT 62 GC P L207 Bar LED ...
Page 39: ...EXPLATION FOR MICOM CIRCUIT 68 GC P L207 Bar LED ...
Page 40: ...EXPLATION FOR MICOM CIRCUIT 69 GC P L207 Bar LED ...
Page 41: ... GC P L207 Bar LED EXPLATION FOR MICOM CIRCUIT 78 ...
Page 42: ...EXPLATION FOR MICOM CIRCUIT 79 PWBASSEMBLY DISPLAY ...
Page 49: ...CIRCUIT 94 GC P L B C207 Bar LED The circuit has been only applied to voltage except 220v ...
Page 100: ......