8
-
5. How to check the F an-E rror
(1) ~ J uly 2007
After sending a signal to the fan, the MIC OM checks the B LDC fan motor’s lock status. If there is no
feedback signal from the B LDC fan, the fan motor stops for 10 seconds and then is powered again for 15
seconds. To determine that there is a fan motor malfunction, this process is repeated 5 times. If the fan
motor is determined to be defective, the error code will be shown continuously in the display.
At this point, there is no further check of the fan motor.
(2) Aug 2007 ~
After sending a signal to the fan, the MIC OM checks the B LDC fan motor’s lock status. If there is no
feedback signal from the B LDC fan, the fan motor stops for 10 seconds and then is powered again for 15
seconds. To determine that there is a fan motor malfunction, this process is repeated 3 times. If the fan
motor is determined to be defective, the error code will be shown in the display for 30 minutes.
At this point, the process will be repeated until the fan motor operates normally. If normal operation is
achieved, the error display is erased and the MIC OM is reset automatically.
R eference
Summary of Contents for GBB530***F Series
Page 35: ... 35 CIR CUIT DIAGR AM A ...
Page 36: ... 36 CIR CUIT DIAGR AM Linear A ...
Page 37: ... 37 CIR CUIT DIAGR AM Linear A FLB compressor ...
Page 39: ...CIR CUIT DIAGR AM 39 A A ...
Page 40: ...CIR CUIT DIAGR AM 40 A HIT Model MEZ64799002 ...
Page 41: ...CIR CUIT DIAGR AM 41 A BMG ...
Page 42: ...CIR CUIT DIAGR AM 4 A BMG ...
Page 43: ...CIR CUIT DIAGR AM 4 A FMA ...
Page 50: ... Figure 24 LOKRING TOOL Figure 23 LOKRING TR OUB LE S HOOTING Mechanical Part ...
Page 64: ... 6 2 Dis play PCB P No E B R 7 6 4 5 6 7 Picture PCB Picture ACQ838523 EBR364958 ...