4
-
2. P TC AND OL P
Normal operation of
C ompressor is
impossible or poor.
S eparate the P TC
from C ompressor and
measure the
resistance between
No. 5 and 6 (only
R S IR Type) or No.
4 and 5 of P TC with a
Tester or Whistone
B ridge. (F igure 22)
S eparate the OLP
from C ompressor and
check resistance value
between two terminals
of OLP with a Tester.
(F igure 23)
C heck another
electric components.
R eplace
P TC .
Observation value is
220V/50Hz : 47Ω ±30%
220-240V/50Hz : 47Ω ±30%
110-115V/60Hz : 6.8Ω ±30%
220V/60Hz : 47Ω ±30%
127V/60Hz : 22Ω ± 30%
The resistance value is
0 or several
hundreds Ω
The value is ∞ .
C heck another
electric components.
Y E S
NO
R eplace OLP .
TR OUB L E S HOOTING (Mechanical P art)