LDO block
There are 6 LDOs in the ADP3408
Table 3-6.
Battery charging block
It can be used to charge Lithium Ion and/or Nickel Metal Hydride batteries. G5200 use Li-Ion battery
only. Charger initialization, trickle charging, and Li-Ion charging control are implemented in
hardware.
Charging Process
Check charger is inserted or not
If ADP3408 detects that Charger is inserted, the CC-CV charging starts.
Exception: When battery voltage is lower than 3.2V, the precharge (low current charge mode) starts
firstly.
And the battery voltage reach to 3.2V the CC-CV charging starts.
Pins used for charging
CHARGERDETECT: Interrupt to AD6522 when charger is plugged.
CHARGEEN: Control signal from AD6522 to charge Li+ battery
EOC: Interrupt to AD6522 when battery is fully charged
GATEIN: Control signal from AD6522 to charge NiMH battery. But, not used.
MVBAT: Battery voltage divider. Divide ratio is 1:2.3 and it is sensed in AD6521 AUX_ADC
TA (Travel Adaptor)
Input voltage: AC 85V ~ 260V, 50~60Hz
Output voltage: DC 5.2V ( ±0.2 V )
Output current: Max 850mA ( ±50mA )
Battery
Li-ion battery (Max 4.2V, Nom 4.0V)
Standard battery : Capacity - 750mAh, Li-ion
3. TECHNICAL BRIEF
- 27 -
Description
VSIM
2.86 V (is provided to SIM card)
VCORE
2.45 V (is provided to the AD6522 & AD6521’s digital core)
VRTC
2.45 V (is provided to the RTC and Backup Battery)
VAN
2.45 V (is provided to the AD6521 I/O and used as microphone bias)
VTCXO
2.715 V (is provided to VCTCXO)
VMEM
2.80 V (is provided to Flash)
Summary of Contents for G5200
Page 22: ...3 TECHNICAL BRIEF 21 Figure 3 7 System interconnection of AD6522 external interfaces ...
Page 37: ...4 TROUBLE SHOOTING 36 RX Check Area ...
Page 38: ...4 TROUBLE SHOOTING 37 4 1 1 Checking Regulator Circuit U414 1 U414 6 ...
Page 43: ...4 TROUBLE SHOOTING 42 4 1 5 Checking Saw Filter Circuit U407 3 U407 1 U408 3 U408 1 ...
Page 45: ...4 2 Tx Trouble 44 4 TROUBLE SHOOTING 6 1 3 3 4 2 5 Rx Check Area ...
Page 53: ... 52 4 TROUBLE SHOOTING 4 2 7 Receiver RF Level GSM CH 62 60dBm DCS CH 699 60dBm ...
Page 54: ... 53 4 TROUBLE SHOOTING Test Points of Rx Level 1 3 4 2 ...
Page 64: ... 63 4 TROUBLE SHOOTING The charging current will flow into this direction R102 D101 U102 ...
Page 65: ...4 TROUBLE SHOOTING 64 4 5 LCD Trouble Setting Connect PIF and power on ...
Page 69: ...4 TROUBLE SHOOTING 68 The waveforms of the audio signals at each point U202 4 U202 5 C206 REC ...
Page 74: ...4 TROUBLE SHOOTING 73 C118 R105 R108 R110 R112 Q101 3 MIC101 C132 C129 ...
Page 79: ...4 TROUBLE SHOOTING 78 Q302 2 R321 R319 ...
Page 83: ...4 TROUBLE SHOOTING 82 PIN 5 PIN 3 PIN 1 PIN 7 ...
Page 85: ...4 TROUBLE SHOOTING 84 ...
Page 86: ...4 TROUBLE SHOOTING 85 ...
Page 87: ...4 TROUBLE SHOOTING 86 ...
Page 91: ...4 TROUBLE SHOOTING 90 ...
Page 92: ...4 TROUBLE SHOOTING 91 ...
Page 108: ...7 BLOCK DIAGRAM 107 7 2 FPCB Figure 7 2 FPCB Blockdiagram 7 3 RF Figure 7 3 RF Blockdiagram ...
Page 109: ...7 BLOCK DIAGRAM 108 ...
Page 114: ... 113 9 PCB LAYOUT 9 PCB LAYOUT ...
Page 115: ... 114 9 PCB LAYOUT ...
Page 135: ...MEMO 134 ...