4. TROUBLE SHOOTING
- 61 -
4.10 Vibrator Trouble
4.10 Vibrator Trouble
SETTING: After initialize Agilent 8960, Test in EGSM, connect PIF to
the phone, and Power on. Enter
The engineering mode, and set
“Vibrator on”at Vibration of BB test menu
START
Is the voltage at pin 3 of
Q500 near 0V?
Check the soldering
of R500
Replace Q500
Yes
No
No
Yes
Check the soldering of
R501
No
Yes
Re-solder R500
Check the signal level
of CN500
Re-solder Vibrator connector
No
Yes
Replace Vibrator
Vibrator
Working!!
Yes
Re-solder R501
Summary of Contents for G1610