15
PDP 60” - SERVICING
SERVICING
Example below is in NTSC mode.
The values are different for DTV mode:
7. Using the
CUSTOMER’S REMOTE
, use the channel
UP
or
DOWN
keys to scroll through the menu and the
VOLUME UP or DOWN
keys to make the adjustments.
8. To exit the service menu, press the (ENTER) key one
time.
DTV ADJUSTMENTS
9. Press the Channel Up key one time, the following
menu will appear.
HEAT RUN
OFF
AUTO CUTOFF
R-CUT
22
G-CUT
8
B-CUT
23
R-GAIN
14
G-GAIN
12
B-GAIN
13
NOTE: “Heat run” has the following settings: OFF, WHITE,
RED, BLUE, and GREEN.
10. These are for warm up of the unit as well as testing
for defects. This function will also remove minor burn-
in on the display.
DO NOT USE FOR SETTING RGB
DRIVES
.
The following chart shows starting value settings for
adjustments.
NTSC
DTV
VP 0 HEATRUN
OFF
OFF
VP 1 CUTOFF-AUTO
VP 2 R-FINE
16
16
VP 3 G-FINE
16
16
VP 4 B-FINE
16
16
VP 5 R-GAIN
16
16
VP 6 G-GAIN
10
10
VP 7 B-GAIN
3
3
VP 8 R-CUT
151
161
VP 9 G-CUT
94
95
VP 10 B-CUT
25
26
VP 11 (NTSC) DVCO ADJ
OFOO
VP 11 (DTV) AUTO PLL
END
VP 12
DTV Adjustments
11. Using the
CUSTOMER’S REMOTE
, use the Channel
UP
or
DOWN
keys to scroll through the menu and the
VOLUME UP or DOWN
keys to make the adjustments.
12. To exit this portion of the service menu cycle power
off and on.
Summary of Contents for Flatron MU-60PZ10B
Page 4: ......
Page 17: ......
Page 18: ......
Page 23: ...21 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 Video Scan Converter TOP BOTTOM ...
Page 24: ...22 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 AC Line Filter Primary Supply TOP BOTTOM ...
Page 25: ...23 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 Swtich Mode Power Supply TOP BOTTOM ...