14
PDP 60” - SERVICING
SERVICING
SERVICE MENU
Service Menu Adjustments for Plasma Display
Once the Main Video Scan Converter module is installed,
the unit will power on as soon as A/C is applied. The
EEPROM data will be set to Factory default values.
The following charts and instructions will allow you to
set access the service menu and make any necessary ad-
justments during the repair and installation of the PDP.
Adjustments must be done in both NTSC/PC and DTV
Modes
If the unit will power on prior to the replacement of this
Module and the menus can be accessed it recommended
that the servicer access the service menu and record the
data from the original EEPROM.
The Service Remote, which is provided with the service
kit, must be used to access the service menu. Once the
servicer has gained access to the service menu he can
then us the customers remote control to complete the
alignments. For additional information see the Service
literature provided in this kit.
Equipment Needed
:
NTSC Pattern Generator
DTV Pattern Generator.
NTSC/PC ADJUSTMENTS
1. When using THE ZENITH LEARNING REMOTE to make
adjustments to the service menu, the AUX function
must be selected.
2. Press the Channel Down key one time, the following
menu should appear.
Option
1
2
3
4
5
System
NTSC
NTSC
3Sys
3Sys
3Sys
Remocon
NEC
Zenith NEC
NEC
NEC
Language Korean ENG
Portugal Espanol
ENG
50/60
60
60
60
60
60
3. The chart shows default value settings for the ser-
vice adjustments. The OPTION CODE will be set to “5”
which is for the LGE remote control codes. This item
must be changed to “2” to allow the Zenith customer
remote to operate the set and complete the neces-
sary adjustments.
4. This is accomplished by using the manual volume UP
and Down buttons on the unit to enter the option
sub menu shown below.
5. The REMOCOM line item should be highlighted at this
time, using the manual volume control buttons, sim-
ply toggle the setting to indicate Zenith. The op-
tion code should now indicate “2”. You will now be
able to continue the service adjustments as follows.
6. Using the
ZENITH LEARNING REMOTE
, press the Chan-
nel down key one time, the following menu should
appear.
VP 0 BCUT
7
VP 1 RCUT
7
VP 2 R-GAIN
0
VP 3 G-GAIN
0
VP 4 B-GAIN
0
VP 5 S CONTRAST
0
VP 6 S BRIGHT
54
VP 7 S-COLOR
7
VP 8 S-TINT
7
VP 9 S-SHARP
3
VP 10 CTI-LEVEL
0
VP 11 R-Y/R
6
VP 12 G-Y/R
10
VP 13 R-Y/B
9
VP 14 G-Y/B
5
VP 15 GAMMA
7
VP 16 LTI-LEV
0
VP 17 PRE/OVER
1
VP 18 DC-TRAN
0
VP 19 D-PIC
2
VP 20 V-TC
2
VP 21 H-WIDTH
3
VP 22 D-COL
1
VP 23 HD-TC
0
VP 24 SHP-FO
0
CXA2101 0
1 ADJ
2 W/B
3 CXA2101 ADJ
4 EPROM INIT
HEAT RUN
OFF
AUTO CUTOFF
R-CUT
22
G-CUT
8
B-CUT
23
R-GAIN
14
G-GAIN
12
B-GAIN
13
PHASE
15
H-PHASE
187
V-PHASE
53
Summary of Contents for Flatron MU-60PZ10B
Page 4: ......
Page 17: ......
Page 18: ......
Page 23: ...21 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 Video Scan Converter TOP BOTTOM ...
Page 24: ...22 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 AC Line Filter Primary Supply TOP BOTTOM ...
Page 25: ...23 DPDP40 DIAGRAMS PV153 923 03458 DPDP60 Swtich Mode Power Supply TOP BOTTOM ...