- 11 -
220
IBM
Compatible PC
PARALLEL PORT
Power inlet (required)
Power LED
ST Switch
Power Select Switch
(110V/220V)
Control Line
Not used
RS232C
PARALLEL
V-SYNC
POWER
ST
VGS
MONITOR
E
E
V-Sync On/Off Switch
(Switch must be ON.)
F
F
A
A
B
B
C
C
15
10
5
5
6
9
1
1
1
14
13
25
6
5V
5V
5V
4.7K
4.7K
4.7K
74LS06
74LS06
OFF
ON
OFF
ON
11
Video Signal
Generator
Figure 1. Cable Connection
SERVICE OSD
1) Turn off the power switch at the front side of the display.
2) Wait for about 3 seconds and press MENU, POWER switch with 1 second interval.
3) The SVC OSD menu contains additional menus that the User OSD menu as described below.
a) MODULE : To select applied module.
b) NVRAM INIT : EEPROM initialize(24C08)
c) ADC OFFSET : The lowest value of input leves sets to digitally 0(zero).
d) ADC GAIN : The highest value of input levels sets to digitally 255.
e) ADC CAL : W/B balance sets the gain and offset value.
f) ELAPSED CLEAR : To initialize using time.