FOR LG TECHNICIAN
WILL NOT CIRCULATE WATER
Remove foreign mate-
rial.
Remove foreign mate-
rial.
Reconnect or repair
the connector.
Replace PUMP MO-
TOR ASSEMBLY.
Replace the MAIN
PWB ASSEMBLY.
YES
YES
YES
YES
NO
NO
NO
NO
NO
Is the impeller of the drain pump clogged?
Are the Hose Connector and/or Hose clogged?
Is the connector disconnected, disassembled?
Is the coil of the right side of drain pump open
or short circuited? (Coil R is 18-30 Ω)
When checking voltage between the
connectors during spin, is the voltage 220-
240V AC, as the figure?