Settings
101
Due to our policy of continuous product innovation, some specifications may change without notice.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
AWHP
If the port setting is set to [AWHP], set the [AWHP Type] and [Energy Level Setting] options. The
AWHP settings run the heatpump with the energy generated by the surplus power of the system.
If the AWHP function is activated, the AWHP status and AWHP energy flow can be checked on the
HOME screen.
External Shutdown Switch
To use an external shutdown switch, set the [External Shutdown Switch] option to [Installed].
Operating Mode
You can select a operating mode.
PV Self-consumption Mode
This mode operates by minimizing the power used in the system. Power generated from solar power
is supplied to the load and the battery is charged with the remaining surplus power. When the battery
is fully charged, the surplus power is supplied to the grid. If the load used power is greater than the
solar power, the power stored in the battery is used.
ToU Mode
In this mode, charging/discharging is performed for each section by directly inputting the rate applied
for each time period.
Available tables are [Summer/Weekday], [Summer/Weekend], [Winter/Weekday], and [Winter/
Weekend]. You can make up to 24 sections with the designated load type. The load type can be set to
[Off-Peak], [Shoulder], [Peak], or [Super-Peak].
Backup Only Mode
This mode fully charges the battery in case of a power outage. If this mode is selected, the battery is
fully charged and it is not discharged until the mode is changed.