PROBLEM
•
This is normal.
•
Steam is released at different stages of the cycle
for each option.
Cannot see steam
vapor at the
beginning of cycle.
•
MORE TIME pressed.
•
Pressing the MORE TIME button adjusts the
load size from 1to 5 articles or a big load
indicated by in the display.
The display shows:
•
STEAM FRESH™ did
not remove odor
completely.
•
Fabrics containing strong odors should be washed in
a normal cycle.
Odors remain in
clothing after
STEAM FRESH™.
POSSIBLE CAUSES
SOLUTIONS
DISPLAY
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE1
CHECKING PART
CAUSE
•
tE1 error is displayed in the
drying cycle or test mode.
Thermistor of blower
housing
Outlet thermistor open or shorted.
tE2
•
tE2 error is displayed in the
drying cycle or test mode.
Thermistor of steam
generator
Steam generator thermistor open
or shorted.
tE4
•
tE4 error is only displayed in the
test mode.
•
Replace the steam generator.
Water supply pump
When the pump valve is less than
10 in the test mode
E5
PS
EE
•
tE5 error is only displayed in the
test mode.
•
Check the connection between
harness wire and connector.
•
Replace the water supply pump.
Steam generator
Wire Connection
(Black-White-Red)
EE PROM Error
Sensors do not detect that steam
generator is full within 60 seconds.
Wire Connection is wrong.
Wire Connection is loose.
EE PROM operation is adnormal.
•
If water in the steam feeder is
EE error is displayed only in the
test mode
not enough this error may be
displayed. Fill the feeder and
restart the cycle.
•
verify proper connection of the
power cord. (Electric dryer only.)
* PS means power supply.
REMARK
8-3. Display Fault/Error Codes
The error codes below will be displayed when attempting to start a drying cycle or after
activating the Diagnostic Test mode.
nC
NFC module
NFC module open or shorted
nC is displayed only in the
test mode
nU
NFC module
NFC module is wrong
nU is displayed only in the
test mode
22