36
Test 10
Generator Assembly
Caution
Trouble Symptom
Measurement Condition
Before measuring resistance, be sure to turn Power off, and do voltage discharge.
(When discharging, contact the metal plug of Power cord with earth line.)
①
During Steam cycle, Generator Assembly is not heating.
②
During Diagnostic Test, tE4 Error occur.
Turn the Dryer’s Power Off, then measure resistance.
Is resistance 14.3
Ω
(
±
5%) between Heater
terminal
①
and
②
?
YES
NO
• Replace the
Generator
Assembly
• If measured
resistance value is
∞
, replace the
Generator
Assembly too.
Normal condition