COMPONENT TESTING TIPS
7
15
Component
Test procedure
Check result
Remark
Safety
Thermostat
Cover, Front
Heater
Measure resistance of
Terminal to terminal
1) Open at 170°C (-10/+5°C)
Measure resistance of
terminal to terminal
Measure resistance of
Terminal to terminal
Measure resistance of
Terminal to terminal
Measure resistance of
Terminal to terminal
1. Thermostat
(Manual type)
2. Thermistor
(Low temperature)
3. Heater,
Thermistor
4. Motor
Measure resistance by pressing
button When resistance becomes
Resistance value < 5
Ω
Resistance value :
10K
Ω
5% (at 25°C)
Resistance value :
Yellow/White : 28.96
1
Ω
Blue/White : 56.29
2
Ω
Resistance value :
200K
Ω
5% (at 25°C)
Resistance value(20°…):
White / Blue : 24.8
2.5
Ω
Blue / Orange : 21.5
2.0
Ω
Measure resistance of
Terminal to terminal
5. Pump
Resistance value :
205
10
Ω