![LG D2532W Service Manual Download Page 17](http://html.mh-extra.com/html/lg/d2532w/d2532w_service-manual_210576017.webp)
16
ACTIVATING THE DIAGNOSTIC TEST MODE
1. Unit must be in Standby (unit plugged in, display off)
2. Press “
POWER
” while pressing “
MORE TIME
”, and “
LESS TIME
” simultaneously.
DIAGNOSTIC TEST
9
Pressing the
“START/PAUSE”
button
CHECKING
ACTION
DISPLAY
CHECKING POINT
REMARK
None
Once
Electric control
&
Temperature
sensor
Motor
Won’t power up
Defective LED
Thermistor open
Thermistor close
Motor runs
Displays Moisture Sensor Operation:
If moisture sensor is contacted with
damp cloth. The display number is
below 180, in normal condition.
70 ~ 237
Measured
Moisture Value.
Twice
ELECTRIC TYPE
Motor + Heater 1 (1250W)
GAS TYPE
Motor + Valve
Current Temp.
ELECTRIC TYPE : Heater runs
GAS TYPE : GAS Valve runs
(Display the Temperature of
Inside drum.)
During check,
If the door is closed.
Motor & Heater Off
+ Lamp Off
70 ~ 237
Return once “1time”
(See test 4) state.
4 times
Control Off
Auto Off
3 times
ELECTRIC TYPE
Motor + Heater 1
+ Heater 2
(5400W)
GAS TYPE
Motor Type
Current Temp.
(5 ~ 70)
See test 5
Off
automatically
after 5
minutes
In normal state if displayed
temp. is increasing.
Temperature in 4min : 113°F (45°C)
• Above : 1” on , 1” off beep sound
• Under : 0.5” on, 0.5”
off beep sound
During check,
If the door is open.
Motor & Heater Off
+ Lamp On +
Buzzer beeps five
times
Door switch
See test 6
Lamp
See test 1
Display : See page
See test 2
See test 3
See test 4
Gas valve
See test 7
1. This TEST should be used for Factory test /Service test. Do not use this DIAGNOSTIC TEST other than
specified.
2. Activating the Heater manually with the Door open may trip the Thermostat attached to the Heater, therefore do
not activate it manually. (Do not press the door switch to operate the heater while the door is open )