- 65 -
3. TECHNICAL BRIEF
3.10.6. Folder ON/OFF Operation
There is a magnet to detect the Slide status, opened or closed.
If a magnet is close to the hall-effect switch, the voltage at pin OUT of U701 goes to 0V. Otherwise,
2.7V. This folder signal is delivered to MSM6280 GPIO92.
LGE Internal Use Only
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Figure. Schematic of Folder ON/OFF detection circuit
Rev.C
SLIDE DETECT
0.1u
VDD
VSS
4
VREG_MSMP_2.7V
C701
EM-1681-FT
U701
NC
3
2
OUT
1
FOLDER_DETECT
Z3X-BOX.COM