23
ENGLISH
Using the Energy Control
Function(Optional)
1
Turn the appliance on.
2
Press
ENERGY CTRL
button.
•
Press
ENERGY CTRL
button repeatedly to
select each step.
NOTE
•
1 step : The power Input is decreased by 20%
compared to rated power input.
−
is displayed on the display screen.
•
2 step : The power Input is decreased by 40%
compared to rated power input.
−
is displayed on the display screen.
•
3 step(Optional) : The power Input is decreased by
60% compared to rated power input.
−
is displayed on the display screen.
•
(1 step), (2 step) is displayed on some indoor
units.
•
This function is available with Cooling Mode.
•
Capacity may decrease when Energy Control mode
is selected.
•
Desired temperature is displayed about 5 seconds
if you press
FAN SPEED
,
or button.
•
Room temperature is displayed about 5 seconds if
you press
ROOM TEMP
button.
Using the Generator Mode
Function(Optional)
This function operate air conditioner under the
previously set power consumption.
•
Turn the appliance on.
•
Press GEN MODE button.
−
is displayed on some indoor units.
NOTE
•
It is not displayed on the remote control display.
•
This function is available with Cooling Mode.
•
This function is disabled when you press
MODE
or
JET MODE
button.
•
When using Generator Power Supply, air
conditioner must use ‘Gen Mode’.(It may not
operate properly in Normal Mode)
•
When using Generator Power Supply, If there
are many applications being used together, air-
conditioner may not operate properly for overload
on Generator.
•
Generator should be maintained properly
according to Manufacture’s Manual. Non-properly
maintained Generator may cause unexpected
effect on air-conditioner (Engine Oil, Fuel Level and
continuous usage time should be in Manufacture’
recommended condition)
•
Due to ‘Gen Mode’, inadequate cooling capacity
•
‘Gen Mode’ is memorized. (In case of restarting the
Air-Conditioner during ‘Gen Mode’. It operates ‘Gen
Mode’ automatically.)
•
When using Generator Power Source, Outdoor
Unit may operate the outdoor fan Automatically for
protecting the Air-Conditioner.