background image

Owner's Manual 

3

Safety Precautions

ENGLISH

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.

Meanings of symbols used in this manual are as shown below.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

Be sure not to do.

Be sure to follow the instruction.

Always use a power plug and socket with
a ground terminal. 

• There is a risk of electric shock.

Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse. 

• There is risk of fire or electric shock .

Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.

• Otherwise it can cause electric shock or fire.

For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.

• There is risk of fire or electric shock.

Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.

• There is risk of fire or electric shock.

Install the panel and the cover of control
box securely. 

• There is risk of fire or electric shock due to

dust , water etc.

Use the correctly rated breaker or fuse. 

• There is risk of fire or electric shock.

Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.

• There is risk of fire or electric shock.

For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.

• There is risk of fire, electric shock, explosion, 

or injury.

Do not install the product on a defective
installation stand. Be sure that  the
installation area does not deteriorate with
age. 

• It may cause product to fall. 

Never install the outdoor unit  on a
moving base  or a place from  where  it
can fall down.

• The falling outdoor unit can cause damage or

injury or even death of a person.

When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.

• There is risk of fire or eletric shock.

In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.

• An charged capacitor can cause electrical

shock.

When installing the unit, use the
installation kit provided with the product.

• Otherwise the unit may fall and cause severe

injury.

Be sure to use only those  parts which
are  listed in the svc  parts list. Never
attempt to modify the equipment. 

• The use of inappropriate parts can cause an

electrical shock, excessive heat generation or fire.

Summary of Contents for ASNW093ERH0

Page 1: ...MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference P NO MFL39817415 TYPE WALL MOUNTED Models ASNW093ERH0 ASUW093EUH0 www lg com ENGLISH ESPAÑOL ...

Page 2: ...to ensure that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 7 Outdoor Unit 7 D Operating In...

Page 3: ...ecurely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an ...

Page 4: ... the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repairing the product There is risk of electric shock When the product is not to be used for a long time disconn...

Page 5: ...used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace...

Page 6: ...ied electrician We strongly discourage the use of an adapter due to potential safety hazards For temporary connections use only a genuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the...

Page 7: ...ting system Timer Lights up during timer operation non Inverter Model Lights up during timer operation or sleep mode auto operation Inverter Model only Defrost mode Power Display Indicates the setting temperature and operation mode Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot...

Page 8: ...e controller starts fading replace both of the batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 ...

Page 9: ...R SET CANCEL BUTTON Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON OPTIONAL Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON OPTIONAL For inverter type models 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON OPTIONAL Used to star...

Page 10: ...eover Heat Pump Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C 64 F 86 F and for heating the temperature range is 16 C 30 C 61 F 86 F Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDO...

Page 11: ...r cooling function of the air conditioner But during this operation the controller changes the operation mode automatically to keep the temperature within 2 C with respect to the setting temperature Operating Instructions In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel ho...

Page 12: ...heat function available only in some models warms up the room quickly by operating at super high fan speed and 30 C 86 F setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air ...

Page 13: ...ou want to stop operation re press the button ON OFF button Heat pump Model Cooling Model RoomTemp 24 C 75 2 F 21 C 69 8 F RoomTemp 24 C 75 2 F RoomTemp 21 C 69 8 F Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 71 6 F 22 C 71 6 F 23 C 73 4 F 24 C 75 2 F Test operation During the TEST OPERATION the unit operates in cool...

Page 14: ...umidification mode The setting temperature will rise automatically two times by 1 C 2 F over next consecutive 30 minutes 2 C 4 F in 1 hour for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the ...

Page 15: ...he same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTE CHAOS Air economizes power cons...

Page 16: ...air filters behind the front panel grill should be checked and cleaned once in every 2 weeks or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner or warm soapy water If dirt is not easily removed wash with a solution of detergent in luke warm water Dry well in shade after washing and reinstall the filters bac...

Page 17: ...ctricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean th...

Page 18: ...ip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn it off...

Page 19: ......

Reviews: