13. Installation
Installation of Indoor Unit
Check
1. Compare the flared work with the figure by.
2. If a flared section is defective, cut it off and do
flaring work again.
Inclined
Inside is shiny without scratches
Smooth all round
Even length
all round
Surface
damaged
Cracked Uneven
thickness
= Improper flaring =
1. Hook the indoor unit onto the upper portion of the
installation plate.( engage the two hooks at the top of
the indoor unit with the upper edge of the installation
plate) Ensure that the hooks are properly seated on
the installation plate by moving it left and right
2. Pull the screw cap at the bottom of the vane.
Remove the chassis cover from the unit by loosing 2screws.
(Be careful no to scratch product)
3. Unlock the tubing holder from the chassis and mount
between the chassis and installation plate in order to
separate the bottom side of the indoor unit from the wall
Tubing Holder
1
2
Installation plate
Chassis Cover