background image

- 7 -

Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

Outdoor Unit

554031

552202

552560

552116

554160

561410

W4986A

W4986B

550140

552203B

552203A

553000

W49810

649950

437211

661400

435301

430410

559010

349480

546810

549610

261704

447910

55211G

552200

263230E

D-pipe Thermistor 

435300

137213B

137213A

435511

268711F

263230D

EEV Coil

Outdoor Air,

Condenser

Thermistor 

Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request.

Please check  the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website  http://biz.Lgservice.com,) 

Summary of Contents for AS-W093ERH0

Page 1: ...oded View MODEL AS W093E H0 LAN095HV LAU095HV AS W123E H0 LAN125HV LAU125HV CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Page 2: ...Filter Prefilter washable anti fungus Auto Clean CHAOS Wind Auto Wind Steps Fan Cool Heat Airflow Direction Control up down Airflow Direction Control left right Remocon Type Setting Temperature Range Cooling C F Heating C F Auto Operation Micom Control Auto Changeover Micom Control Self Diagnosis Timer Sleep Operation Soft Dry Operation Restart Delay minute Deice Control Defrost Hot Start Jet Cool...

Page 3: ...or Gas Side 3 Way Valve 2 Way Valve Liquid Side Cooling Heating Reversing Valve Th1 Th2 Th5 Th4 Th3 LOC Description PCB Connector Th1 Thermistor for indoor air temperature CN_TH1 INDOOR Th2 Thermistor for evaporating temperature CN_TH2 INDOOR Th3 Thermistor for discharge pipe temperature CN_D_PIPE OUTDOOR Th4 Thermistor for condensing temperature CN_TH1 OUTDOOR Th5 Thermistor for outdoor air tempe...

Page 4: ...2009 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 3 Wiring Diagrams CN MOTOR1 CN_L R BL CN_UD WH CN_SUB GRY CN_DISP1 WH CN_TH2 WH CN_TH1 YL CN_HVB BL Indoor Unit ...

Page 5: ...yright 2009 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only CN PUMP HEATER CN 4WAY CN TEST CN PC CN EEV CN D A CN FLASH CN TH1 CN D_PIPE CN FAN2 Outdoor Unit ...

Page 6: ...2150 147581 146811B 135516 146811A 263230A 268711D 268711H 268711G 159830 35211B 268711B 135311 354210 249951 342800 266090 346810 267110 Indoor Air Thermistor Evaporater Thermistor 152313 Option Parts Note Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz L...

Page 7: ...9810 649950 437211 661400 435301 430410 559010 349480 546810 549610 261704 447910 55211G 552200 263230E D pipe Thermistor 435300 137213B 137213A 435511 268711F 263230D EEV Coil Outdoor Air Condenser Thermistor Note Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website ht...

Page 8: ...P NO MFL42286406 April 2009 ...