background image

LG  
Multi Type Air Conditioner

OWNER'S MANUAL

LG

IMPORTANT

• Please read this owner's manual carefully and thoroughly 

before installing and operating your room air conditioner. 

• Please retain this owner's manual for future reference after 

reading it  thoroughly.

Prior to installation, this air-
conditioning unit must be submitted
for approval by the utility service
which provides electricity 
(EN 61000-2, EN 61000-3 Norm).

ENGLISH

FRANÇAIS

ESPAÑOL

Summary of Contents for Art Cool LMAN090HNS

Page 1: ...ore installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm ENGLISH FRANÇAIS ESPAÑOL ...

Page 2: ...chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play with the air c...

Page 3: ...t to do Be sure to follow the instruction WARNING Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the p...

Page 4: ...duct on a defective installation stand It may cause injury accident or damage to the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open Moisture...

Page 5: ...nge sounds or small or smoke comes from product Turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire When the product is soaked flooded or submerged contact an Authorized Service Center There is risk of fire or electric shock When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product...

Page 6: ...amage property It may cause a problem for your neighbors Use two or more people to lift and transport the product Avoid personal injury Do not install the product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 Do not expose the skin...

Page 7: ...ct malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury ...

Page 8: ...h usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and breaker are turned off There is a possibility of injury...

Page 9: ...direction 2 Insert new batteries making sure that the and of battery are installed correctly 3 Reattach the cover by sliding it back into position Use 2 AAA 1 5volt batteries Do not use rechargeable batteries NOTICE The remote control may be stored mounted on a wall To operate the room air conditioner aim the remote control at the signal receptor The remote control will operate the air conditioner...

Page 10: ...uto operation Timer Lights up during Timer operation Defrost Mode Outdoor unit operation Lights up during Defrost Mode or Hot Start operation Heat pump model only Lights up during outdoor unit operation Cooling model only On Off Operation indication lamps Desire temperature For cooling dehumidification heating modes it display Destired temperature indicator Cooling 18 C 30 C 64 F 86 F AI Auto Oper...

Page 11: ...TON Used to stop or start louver movement and set the desired up down airflow direction ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation AIR CIRCULATION...

Page 12: ...on of the arrow Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C 64 F 86 F in 1 C 2 F You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Cooling Operation Natural wind by the CHAOS logic For more fresh feeling press the Indoor Fan Speed Selector and set CHAOS mod...

Page 13: ...trols based on the actual room temperature If you want to change the set temperature press the Room Temperature Setting buttons The set temperature will be changed considering room temperature DURING AUTO OPERATION You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The system will not automatica...

Page 14: ...humidification mode on the operation selection button the A C starts to run the dehumidification function automatically setting the room temp and air volume to the best condition for dehumidification based on the sensed room temp In this case the setting temp is not displayed in the Remote Controller and you are not able to control the room temp either During the healthy dehumidification function ...

Page 15: ... in the direction of the arrow NATURAL WIND BY THE CHAOS LOGIC For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic 1 2 Set the temperature higher than the room temperature The temperature can be set within a range of16 C 30 C 60 F 86 F i...

Page 16: ...ll operate in high fan speed in cooling heating mode 1 2 3 Jet Cool function in heating mode is available on Artcool type only During the JET COOL function at any moment the A C starts to blow the cool heat air at extremely high speed for 30 60 minutes setting the room temp automatically to 18 C 30 C 64 F 86 F It is especially used to cool heat the room temperature in the shortest time In order to...

Page 17: ...hen the button is pressed and stop when the button is pressed again Set the fan speed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA is available in Heating or any other operations 1 2 3 NEO PLASMA Purification Operation Optional If you press the PLASMA button NEO PLASMA air purifying ...

Page 18: ...und Open the door of the Remote Controller and press the 2nd F button to operate functions printed in blue at bottom of buttons Check the indication of 2nd function on Remote Controller display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page 1 2 3 ...

Page 19: ...ally rise by 1 C 2 F over the next 30 minutes and by 2 C 4 F in 1 hour for comfortable sleeping NOTICE 1 Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button 2 Press the Time Setting buttons until the desired time is set 3 Press the Timer SET button Check the indicator fo...

Page 20: ...n the room evenly and at the same time to make the human body feel most comfortable as if enjoying a natural breeze Always use the remote control to adjust the up down airflow direction Manually moving the vertical airflow direction louver by hand could damage the air conditioner When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTICE The ...

Page 21: ...start the unit 2 Press CHAOS SWING BUTTON 3 The louvers will swing up down automatically 4 To stop the louver at a desired angle press again The left right Horizontal airflow can be adjusted by using the remote control 1 Press the START STOP BUTTON to start the unit 2 Press the HORIZONTAL AIRFLOW DIRECTION BUTTON 3 The louvers will swing left right automatically 4 To stop the louvers at a desired ...

Page 22: ... mode the fan operates at a low speed and the compressor starts about 3 minutes later As the compressor starts the fan speed also resumes its previous setting mode Helpful information Fan speed and cooling capacity The cooling heating capacity indicated in the specification is the value when the fan speed is set to high and the capacity will be lower at low or medium fan speed High fan speed is re...

Page 23: ...orward to remove the filter 2 Clean the filter with a vacuum cleaner or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C 104 F or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Gasoline Powder Vertical louver Horizontal louver Air filters behind front panel Air outlet v...

Page 24: ...uum or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C 104 F or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE 24 Room Air Conditioner Maintenance and Service Replacement of purifying filter Optional Recommended use period About 2 years Open the front panel as shown Th...

Page 25: ... the Air filter 2 Remove the Plasma Filter 3 Put in Plasma Filters in the neutral detergent for 1 2 hours and then raise them 4 Insert the Plasma Filter after perfectly drying in shade Now insert Air Filter and close the Front panel Completely by matching the hook Air Filter Air Filter Front Panel Hook Hook Hanger Air Filter Plasma Purifier Filter Front Panel ...

Page 26: ... Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows if possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operati...

Page 27: ...h items in the room Check the drain hose is connected tight or if indoor unit is installed even This is the protector of the mechanism Wait about 3 minutes and operation will begin About 3 minutes delay is applied to protect compressor from frequenty on off Is the air filter dirty See air filter cleaning instructions Has the temperature been set correctly Are the indoor unit s air inlet or outlet ...

Reviews: