23
Zone
Flex Multi Split
Indoor Units
Outdoor Units
Model
LMN090CE
LMAN090CNS
LMN120CE
LMAN120CNS
LMAN121CNM
LMN090HE
LMAN090HNS
LMN120HE
LMAN120HNS
LMAN121HNM
LMU240CE
LMU360CE
LMU240HE
LMU360HE
Indoor
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
36V DC
BTUs
9,000
9,000
12,000
12,000
12,000
9,000
9,000
12,000
12,000
12,000
24,000
36,000
24,000
36,000
Electrical Specifications
Outdoor
—
—
—
—
—
—
—
—
—
—
230/208
230/208
230/208
230/208
Voltage
*Minimum Circuit Ampacity
**Maximum Overcurrent Protection
Wire Size
Minimum AWG
14-3
Indoor/Outdoor Connecting Cable Minimum AWG
18-4
Flex Multi Split
Type
A/C
A/C
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
Model
LMN090CE
LMAN090CNS
LMN120CE
LMAN120CNS
LMAN121CNM
LMN090HE
LMAN090HNS
LMN120HE
LMAN120HNS
LMAN121HNM
Pipe size
Liquid
Suction
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
1/4"
BTUs
9,000
9,000
12,000
12,000
12,000
9,000
9,000
12,000
12,000
12,000
Additional
Refrigerant
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
0.21 oz./ft.
Max. length
each pipe
50'
50'
50'
50'
50'
50'
50'
50'
50'
50'
Max.
elevation
25'
25'
25'
25'
25'
25'
25'
25'
25'
25'
Refrigerant Line & Formula Specifications***
25' maximum
8' minimum
16.4' maximum
OIL TRAP
INDOOR UNIT
OUTDOOR UNIT
3/8"
3/8"
3/8"
3/8"
3/8"
3/8 "
3/8"
3/8"
3/8"
3/8"
HIGH WALL DUCT- FREE
•
FLEX MULTI SPLIT
• DUAL & TRI ZONE
ELECTRICAL & REFRIGERATION
•
QUICK REFERENCE
NOTE: Please see local electrical codes for proper wire specifications.
All equipment single phase.
Type
A/C
A/C
A/C
A/C
A/C
H/P
H/P
H/P
H/P
H/P
A/C
A/C
H/P
H/P
Rated
Amps
0.5
1.3
0.5
1.3
0.5
0.5
1.3
0.5
1.3
0.5
11.1
16.6
11.1
16.6
MCA
*
—
—
—
—
—
—
—
—
—
—
20
20
20
20
MOP
**
—
—
—
—
—
—
—
—
—
—
20
30
20
30
***Dual Zone: exterior unit has sufficient refrigerant for charging two indoor coils and a 25 ft. line set per indoor unit.
Tri Zone: exterior unit has sufficient refrigerant for charging three indoor coils and a 25 ft. line set per indoor unit.
NOTE: Systems having the outdoor unit mounted above the indoor unit (e.g. basement installations) have the
following additional requirement:
For systems with maximum elevation of 25 ft. (see chart above and Figure A), refrigerant lines must be oil
trapped between 8 ft. and 16.4 ft. of elevation.
For systems with elevation of greater than 25 ft. (see chart above), refrigerant lines must be oil trapped at least
every 16.4 ft. of elevation.
Figure A.
Example: 25 ft. maximum elevation.