10
Single Zone
Art Cool Gallery W
all Mounted Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
GENERAL DATA
Table 1: Art Cool Gallery Unit Specifications - Continued
Art Cool Gallery Unit Specifications
EEV: Electronic Expansion Valve IDU: Indoor Unit ODU: Outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
5
Piping lengths are equivalent.
Type
Art Cool Gallery
Art Cool Gallery
System (Model)
LA090HVP (LAN090HVP/LAU090HVP)
LA120HVP (LAN120HVP/LAU120HVP)
Piping
Liquid Line (in, OD)
1/4
Vapor Line (in, OD)
3/8
Condensation Line (OD | ID)
27/32 | 5/8
Additional Refrigerant Charge (oz/ft)
0.22
Pipe Length (Min/Max) (ft)
5
9.8/49.2
Piping Length (no add’l refrigerant, ft)
5
24.6
Max Elevation Difference (ft)
22.9