background image

ENGLISH

Safety Precautions   

Ownerʼs Manual 

5

Installation

CAUTION

Always check for gas (refrigerant) leakage
after installation or repair of product.

• Low refrigerant levels may

cause failure of product.

Install the drain hose to ensure that
water is drained away properly.

• A bad connection may cause

water leakage.

Keep level even when installing
the product. 

• To avoid vibration or water

leakage.

Operation

Do not install the product where the noise
or hot air from the outdoor unit could
damage the neighborhoods.

• It may cause a problem for your

neighbors.

Use two or more people to lift and
transport the product. 

• Avoid personal injury.

Do not install the product where
it will be exposed to sea wind
(salt spray) directly.

• It may cause corrosion on the product.

Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation.

Do not expose the skin directly
to cool air for long periods of
time. (Don't sit in the draft.)

• This could harm to your health.

Do not use the product for special
purposes, such as preserving foods,
works of art, etc. It is a consumer air
conditioner, not a precision
refrigeration system.

• There is risk of damage or loss

of property.

Do not block the inlet or outlet
of air flow.

• It may cause product failure.

Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.

• There is risk of fire, electric

shock, or damage to the plastic
parts of the product.

Do not touch the metal parts of the
product when removing the air
filter. They are very sharp!

• There is risk of personal injury.

Do not step on or put anyting
on the product. (outdoor units)

• There is risk of personal injury

and failure of product.

Always insert the filter securely.
Clean the filter every two weeks
or more often if necessary.

• A dirty filter reduces the efficiency of

the air conditioner and could cause
product malfunction or damage.

Do not insert hands or other objects
through the air inlet or outlet while the
product is operated.

• There are sharp and moving parts

that could cause personal injury.

Do not drink the water drained
from the product.

• It is not sanitary and could cause

serious health issues.

If the liquid from the batteries gets onto your skin
or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked.

• The chemicals in batteries could cause burns or

other health hazards.

If you eat the liquid from the batteries, brush your
teeth and see doctor. Do not use the remote if the
batteries have leaked.

• The chemicals in batteries could cause burns or

other health hazards.

Use a firm stool or ladder when
cleaning or maintaining the
product.

• Be careful and avoid personal injury.

Replace the all batteries in the remote
control with new ones of the same
type. Do not mix old and new batteries
or different types of batteries.

• There is risk of fire or explosion

Do not recharge or
disassemble the batteries. 
Do not dispose of batteries in a
fire.

• They may burn or explode.

COOLING MODE

OPERATING TEMPERATURE(°C)

INDOOR

OUTDOOR

MAX.

MIN.

MAX.

MIN.

32°C

21°C

43°C

21°C

HEATING MODE

INDOOR

OUTDOOR

MAX.

MIN.

MAX.

MIN.

27°C

20°C

24°C

1°C

Summary of Contents for ARNU18GS8R2

Page 1: ... com OWNER S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference TYPE ART COOL Mirror ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH PORTUGUESE π DUTCH êìëëäàâ üáõä ...

Page 2: ...g tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they d...

Page 3: ...roduct There is risk of fire or electric shock Install the panel and the cover of control box securely There is risk of fire or electric shock Always install a dedicated circuit and breaker Improper wiring or installation may cause fire or electric shock Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable There is risk of fire or ...

Page 4: ...d Service Center There is risk of fire or electric shock Be cautious that water could not enter the product There is risk of fire electric shock or product damage Ventilate the product from time to time when operating it together with a stove etc There is risk of fire or electric shock Turn the main power off when cleaning or maintaining the product There is risk of electric shock Operation Do not...

Page 5: ...arts of the product when removing the air filter They are very sharp There is risk of personal injury Do not step on or put anyting on the product outdoor units There is risk of personal injury and failure of product Always insert the filter securely Clean the filter every two weeks or more often if necessary A dirty filter reduces the efficiency of the air conditioner and could cause product malf...

Page 6: ...recision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and br...

Page 7: ...g timer operation or sleep mode auto operation Defrost mode Power Display Indicates the setting temperature and operation mode Cooling heating auto operation dehumidification mode Lights up during defrost mode or hot start operation Heat pump model only Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost mode unit stop...

Page 8: ...erature button It will set not room temperature but outlet air temperature 3 Fan speed button Fan Speed have 3 Steps Middle and Low step is same 4 ON OFF button 5 Opration mode selection button 6 Wireless remote controller receiver Some products don t receive the wireless signals 7 Air flow button 8 Subfunction button 9 Function setting button 10 Ventilation button 11 Reservation 12 Up down left r...

Page 9: ...inosity 6 Smart clean button optional Used to start or stop smart clean 7 Clear all button Used to clear all timer 8 Room temperature setting button Used to select the room temperature 8 ON OFF button Used to turn off on the unit 10 Indoor fan speed selection button Used to select fan speed in four steps low medium high and chaos 11 Auto swing button Used to stop or start louver movement and set t...

Page 10: ...tall the filters back in place Plasma Filters The plasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodor...

Page 11: ...ll it in the indoor unit Refer to page 10 for cleaning it Check that the air inlet and outlet of the indoor outdoor unit are not blocked Check that the ground wire is connected correctly It may be connect to the indoor unit side Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air condi...

Page 12: ...faint or no display at all Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed For a noise that sounds like water flowing This is the sound of freon flowing inside the air condit...

Page 13: ......