Date:
Job
Name/Location:
PO
No.:
Architect:
Engr:
GC:
Rep:
For:
File
Approval
Mech:
Resubmit
Other
(Company)
(Project
Manager)
Tag
#:
ARNU123SER2
Multi
V
Art
Cool™
Mirror
Performance:
Cooling
Nominal
Test
Conditions:
Heating
Nominal
Test
Conditions:
Indoor:
80°F
DB/67°F
WB
Outdoor
:
95°F
DB
Indoor:
70°F
DB
Outdoor
:
47°F
DB/43°F
WB
Heating
Capacity
(Btu/h)
13,600
Electrical:
Power
Supply
(V/Hz/Ø)
208
‐
230/60/1
Rated
Amps
(A)
0.3
Piping:
Refrigerant:
Liquid
Line
(in,
OD)
1/4
Flare
Vapor
Line
(in,
OD)
1/2
Flare
Condensate:
Controls
Features:
Unit
Data:
Refrigerant
Type
R410A
Refrigerant
Control
EEV
Net
Unit
Weight
(lbs)
25
Shipping
Weight
(lbs)
29
Primary
Filter
Washable
Pre
‐
filter
Secondary
Filter
Plasma
Fan:
Type
Cross
Flow
Quantity
1
Motor/Drive
Brushless
Digitally
Controlled/Direct
Airflow
Rate
H/M/L
(CFM)
353/283/212
Power
Input¹
(W)
40
Condensate
Line
(in,
OD)
5/8
Entering
Mixed
Air:
Heating
Min
(°F
DB)
59
Standard
Features:
•Limited
Warranty
with
LG
Cer
fi
ed
Installa on
•Two
Year
Func onal
Parts
Warranty
•Standard
Mirror
Front
Panel
Notes:
Total
Cooling
Capacity
(Btu/h)
12,300
12,300 Btu/h
Indoor
Unit
Factory
Installed
Pump
No
Cooling
Max²
(°F
WB)
76
Sound
Pressure³
dB(A)
(H/M/L)
41/36/27
•Auto
changeover
(Heat
Recovery
only)
•Auto
opera on
•Auto
clean
(coil
dry)
•Auto
restart
•Child
lock
•Dual
thermistor
control
•Forced
opera on
•Group
control
•Hot
start
•Self
diagnos cs
•Sleep
mode
•Timer
(on/o
ff
)
•Weekly
schedule
•So
dry
(dehumidi
fi
ca on)
•Auto
direc on/swing
(up/down)
•Auto
direc on/swing
(le /right)
•Fan
speed
control
•Chaos
swing
(random
louver
swing)
•Chaos
wind
(random
fan
speed)
•Jet
cool
(fast
cooling)
1.The
Power
Input
is
rated
at
high
speed.
2.See
Engineering
Manual
for
sensible
and
latent
capaci es.
3.Sound
Pressure
levels
are
tested
in
an
anechoic
chamber
under
ISO
Standard
1996.
4.All
communica on
cable
to
be
minimum
18
AWG,
2
‐
conductor,
stranded,
shielded
and
must
comply
with
applicable
local
and
national
code.
5.Power
wiring
cable
size
must
comply
with
the
applicable
local
and
na onal
code.
6.This
unit
comes
with
a
dry
nitrogen
charge.
7.This
data
is
rated
0
above
sea
level,
with
25
of
refrigerant
line
per
indoor
unit
and
a
0
level
difference
between
outdoor
and
indoor
units.
All
capacities
are
net
with
a
combination
ratio
between
95
–
105%.
8.Must
follow
installa on
instruc ons
in
the
applicable
LG
installa on
manual.
Page
1
of
2
VRF
‐
SB
‐
DA
‐
003
‐
US
012B07
For
continual
product
development,
LG
reserves
the
right
to
change
specifications
without
notice.
LG
Electronics
U.S.A.,
Inc.,
Englewood
Cliffs,
NJ.
All
rights
reserved.
“LG
Life’s
Good”
is
a
registered
trademark
of
LG
Corp.
/www.lg
‐
vrf.com
Blue
‐
PSAPECB10
Silver
‐
PSAPECV10
Optional
Accessories:
Changeable
Front
Panel
(field
installed):
Wireless
Handheld
Remote
Controller
‐
PQWRHDF0
7
‐
Day
Programmable
Controller
(Black)
‐
PQRCVSL0
Simple
Controller
with
Mode
(Black)
‐
PQRCVCL0Q
Simple
Controller
without
Mode
(Black)
PQRCHCA0Q
Dry
Contact
Unit
‐
PQDSB1
7
‐
Day
Programmable
Controller
(White)
‐
PQRCVSL0QW
Simple
Controller
with
Mode
(White)
‐
PQRCVCL0QW
Simple
Controller
without
Mode
(White)
‐
PQRCHCA0QW
Dry
Contact
Unit
‐
PQDSBC