10
WIRING CONNECTION
ENGLISH
Connecting cables between indoor unit and outdoor unit
Outdoor
unit
Indoor
unit
1
2
3
1
2
3
The power cord connected to the outdoor unit should be complied with IEC 60245 or HD 22.4
S4 (This equipment shall be provided with a cord set complying with the national regulation.
The connecting cable connected to the outdoor unit should be complied with IEC 60245 or
HD 22.4 S4 (This equipment shall be provided with a cord set complying with the national
regulation.)
If the supply cord is damaged, it must be replaced by a special cord or assembly availible
from the manufacturer of its service agent.
When the connection line between the indoor unit and out-
dooor unit is over 40 m, connect the telecommunication line
and power line separately.
CAUTION
!
GN/
YL
20 m
m
35±5 mm
10±3 mm
NORMAL
CROSS-SECTIONAL
AREA 0.75 mm
2
20 mm
GN/Y
L
35±5 mm
10±3 mm
Model
Phase(Ø) Area(mm
2
)
1
2.5
1
0.75
ATUQ24GQSK1
ATUQ18GQSK1
APUQ30GS1K1
APUQ18GS1K1
ATUQ24GQSK1
ATUQ18GQSK1
APUQ30GS1K1
APUQ18GS1K1