background image

2. Function Table

- 3 -

Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

Air supply outlet

1

Airflow direction control(left & right)

-

Airflow direction control(up & down)

-

Auto swing(left & right)

-

Air flow

Auto swing(up & down)

-

Airflow steps(fan / cool / heat)

3 / 3 / 3

Chaos swing

-

Chaos wind(auto wind)

X

Jet cool(Power wind)

X

Swirl wind

X

Deodorizing filter

X

Air purifying

Plasma air purifier

X

Prefilter(washable / anti-fungus)

O

Drain pump

O

Installation

E.S.P. control

O

Electric heater(operation)

X

High ceiling operation

-

Hot start

O

Reliability

Self diagnosis

O

Soft dry operation

O

Auto changeover

X

Auto cleaning

X

Auto operation(artificial intelligence)

O

Auto restart operation

O

Child lock

O

Convenience

Energy-Saving Cooling Mode

X

Forced operation

X

Group control

O

Sleep mode

X

Timer(on/off)

X

Timer(weekly)

X

Two thermistor control

O

Wide wired remote controller

Accessory (PQRCUSA0)

Deluxe wired remote controller

-

Individual

Simple wired remote controller

O

control

Simple wired remote controller(for hotel use)

Accessory (PQRCFCS0C)

Wireless remote controller(simple)

X

Wireless LCD remote control

X

Wireless LCD remote control(Ez)

X

General central controller (Non LGAP)

X

CAC network

Dry contact

Accessory (PQDSB)

function

Central control(LGAP)

X

PDI(power distribution indicator)

X

PI 485

X

Special

CTIE

X

function kit

Zone control

X

Others

Thermistor

-

Function

Category

AMNW18GB2A0 [LMDN185HV]

O : Applied

X : Not applied

– : No relation

Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate

package.

Summary of Contents for AMNW18GB2A0

Page 1: ...ner SVC MANUAL Exploded View CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com MODEL AMNW18GB2A0 LMDN185HV ...

Page 2: ...ower Supply Ø V Hz Capacity Btu h class Current Running Current A Fan Motor Type Fan Type Motor Output W x No of Unit Air Flow Rate CMM H M L CFM External Static Pressure mmAq Capacitor µF Vac Drive Coil Row x Column x FPI Dimensions Body mm inch W x H x D Decorative Panel mm inch Net Weight Body kg lbs Decorative Panel kg lbs Air Filter Sound Level H M L dB A 3 Piping Liquid mm inch Connections G...

Page 3: ...nce Energy Saving Cooling Mode X Forced operation X Group control O Sleep mode X Timer on off X Timer weekly X Two thermistor control O Wide wired remote controller Accessory PQRCUSA0 Deluxe wired remote controller Individual Simple wired remote controller O control Simple wired remote controller for hotel use Accessory PQRCFCS0C Wireless remote controller simple X Wireless LCD remote control X Wi...

Page 4: ... exchanger Th3 Th1 Gas pipe connection port flare connection Th2 Liquid pipe connection port flare connection Cooling Heating Sirocco Fan M LOC Description PCB Connector Th1 Thermistor for sunction air temperature CN_ROOM Th2 Thermistor for evaporator inlet temperature CN_PIPE IN Th3 Thermistor for evaporator outlet temperature CN_PIPE OUT ...

Page 5: ...ectronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 4 Wiring Diagrams CN_REMO CN_PIPE OUT CN_PIPE IN CN_ROOM CN_D PUMP CN_POWER CN_FLOAT CN_MOTOR1 CN_MOTOR2 CN_OPTION CN_DISPLAY CN_CC ...

Page 6: ...SC since the replacement parts may be changed depending upon the buyer Øs request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz Lgservice com 159830 336600A 263230B 263230A 263230C 359012B 354210 268711C 249951 268711E 336600B 346810 352118A 267110 W51620 352150 158591 330871 137211 437213 352118B 359012A ...

Page 7: ...P NO MFL61777608 FEBRUARY 2009 ...

Reviews: