3. Piping Diagrams

Heat exchanger

Th3

Th1

Gas pipe connection port

(flare connection)

Th2

Liquid pipe connection port

(flare connection)

C.F.F

Cooling

Heating

LOC.

Description

PCB Connector

Th1

Thermistor for Inlet air temperature

CN_TH1

Th2

Thermistor for Liquid line temperature

CN_TH1

Th3

Thermistor for Gas line temperature

CN_TH2

Summary of Contents for AMNW09GDEL0

Page 1: ...NUAL Exploded View Model AMNW09GDEL0 LMN095HV AMNW12GDEL0 LMN125HV CAUTION Before Servicing the unit read the safety precautions in Standard SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Page 2: ... Static Pressure mmAq Capacitor µF Vac Drive Coil Row x Column x FPI Dimensions Body mm inch W x H x D Decorative Panel mm inch Net Weight Body kg lbs Decorative Panel kg lbs Air Filter Sound Level H M L dB A 3 Piping Liquid mm inch Connections Gas mm inch Drain OD ID mm inch Dehumidification Rate l h Safety Devices Temperature Sensor Referigerant Referigerant Control Transmission Interunit Cable ...

Page 3: ...er operation High ceiling operation Hot start O O Reliability Self diagnosis O O Soft dry operation O O Auto changeover X X Auto cleaning O O Auto operation artificial intelligence O O Auto restart operation O O Child lock Convenience Energy Saving Cooling Mode X X Forced operation O O Group control Sleep mode O O Timer on off O O Timer weekly Two thermistor control Wide wired remote controller De...

Page 4: ...ing Diagrams Heat exchanger Th3 Th1 Gas pipe connection port flare connection Th2 Liquid pipe connection port flare connection C F F Cooling Heating LOC Description PCB Connector Th1 Thermistor for Inlet air temperature CN_TH1 Th2 Thermistor for Liquid line temperature CN_TH1 Th3 Thermistor for Gas line temperature CN_TH2 ...

Page 5: ...ght 2007 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 4 Wiring Diagrams CN_TH1 CN_DISP3 CN_OPTION CN_12V CN_U D CN_MOTOR CN_L R CN_CC CN_HVB CN_DISP1 CN_TH2 ...

Page 6: ... 159830 147581 268711A 146811 147582 352150 346810 135500 135516 35211B 354210 267110 W6640A 268711C 263230B 263230C 249951 266090 Air Evaporator Thermistor TH2 WH Evaporater Thermistor TH3 RD 268711E Note Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz Lg...

Page 7: ...P NO MFL61777603 Dec 2008 ...