ances or devices, it must be a dedicated power source for this
appliance.

• Do not modify or extend the power cable.
• Ensure the power cable is secure so that it does not come out

while the appliance is operating.

• Do not touch the power plug or the appliance controls with

wet hands.

• Cut the power during a severe thunderstorm or lightening or

when not in use for a long period of time.

• Do not grab the power cable when removing the plug, but

rather hold the power plug tightly.

• Do not bend the power cable excessively or place a heavy ob-

ject on it.

• Do not turn on the circuit breaker or power when covers are

removed or opened.

• Make sure that the pipe and the power cable connecting the

indoor and outdoor units are not pulled too tight when in-
stalling the appliance.

• Install dedicated electric outlet and circuit breaker for the appli-

ance.

• Make sure to close the cover of the control box after connect-

ing the wiring to the appliance.

• Loose connections may cause electrical sparks, injury, and

death.

• Do not install the appliance in a place where flammable liquids

or gases such as gasoline, propane, paint thinner, etc., are
stored.

• Only use the refrigerant designated on the label, do not put

any foreign substances into the appliance.

• Any person who is involved with working on or breaking into a

refrigerant circuit should hold a current valid certificate from an

This symbol indicates that this appliance uses a flam-
mable refrigerant. If the refrigerant is leaked and expo-
sure to an external ignition source, there is a risk of fire.

This symbol indicates that the Operation Manual
should be read carefully.

This symbol indicates that a service personnel should
be handling this equipment with reference to the Instal-
lation Manual.
This symbol indicates that information is available such
as the Operating Manual or Installation Manual.

IMPORTANT SAFETY INSTRUCTIONS

WARNING

To reduce the risk of explosion, fire, death, electric shock, injury
or scalding to persons when using this product, follow basic pre-
cautions, including the following:
• The information contained in the manual is intended for use by

a qualified service technician who is familiar with the safety
procedures and equipped with the proper tools and test instru-
ments.

• The appliance shall be installed in accordance with national

wiring regulations.

• Compliance with national gas regulations shall be observed.
• Means for disconnection must be incorporated in the fixed

wiring in accordance with the wiring rules.

• If the supply cord is damaged, it must be replaced by the man-

ufacturer or its service agents or similarly qualified person in
order to avoid a hazard.

• Appliance shall be disconnected from its power source during

!

service and when replacing parts.

• Failure to read and follow all instructions in this manual can re-

sult in equipment malfunction, property damage, personal in-
jury and/or death.

• Check that the appliance’s voltage level is 90 % or higher than

the rated voltage. To check it, refer to the label attached to the
side of the appliance.

• Do not install the appliance on an unstable surface or in a

place where there is danger of it falling.

• This appliance must be grounded. In the event of malfunction

or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.

• Improper connection of the equipment-grounding conductor

can result in risk of electric shock. Check with a qualified elec-
trician or service personnel if you are in doubt as to whether
the appliance is properly grounded.

• If the power supply cable is damaged or the cable connection

is loose, do not use the power supply cable and contact an au-
thorized service center.

• Do not connect the ground wire to a gas pipe, a lightning rod,

or a telephone ground wire.

• Do not share the power supply for this unit with other appli-

The following symbols are displayed on indoor and outdoor
units. (for R32)

INSTALLATION MANUAL AIR CONDITIONER

TYPE : WALL MOUNTED
Original instruction

MFL67713839

Rev.04_032321

Copyright © 2016 - 2021 LG Electronics Inc. All Rights Reserved.

SAFETY INSTRUCTIONS

The following safety guidelines are intended to prevent
unforeseen risks or damage from unsafe or incorrect operation of
the appliance. The guidelines are separated into ‘WARNING’ and
‘CAUTION’ as described below.

WARNING

This indicates that the failure to follow the instructions can
cause serious injury or death.

CAUTION

This indicates that the failure to follow the instructions can
cause the minor injury or damage to the product.

!

!

This symbol is displayed to indicate matters and
operations that can cause risk. Read the part with this
symbol carefully and follow the instructions in order to
avoid risk.

!

Summary of Contents for AM07BP.NSJ

Page 1: ...he appliance shall be installed in accordance with national wiring regulations Compliance with national gas regulations shall be observed Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the man ufacturer or its service agents or similarly qualified person in order to avoid a hazard Appliance s...

Page 2: ...or con sumer purposes not a precision refrigerant system There is risk of damage or loss of property Do not install the unit in potentially explosive atmospheres Refrigerant for R32 Only WARNING The appliance shall be stored in a well ventilated area where the room size corresponds to the room area as specified for operation The appliance shall be stored in a room without continuously operating op...

Page 3: ... Spanner Torque wrench Multi meter Hexagonal wrench Ammeter Gas leak detector Thermometer Level Flaring tool set Name Select the best Location There should not be any heat or steam near the unit Select a place where there are no obstacles around of the unit Make sure that condensation drainage can be conveniently routed away Do not install near a doorway Ensure that the interval between a wall and...

Page 4: ...rrs removal 1 Completely remove all burrs from the cut cross section of pipe tube 2 While removing burrs put the end of the copper tube pipe in a downward direction while removing burrs location is also changed in order to avoid dropping burrs into the tubing Putting nut on Remove flare nuts attached to indoor and outdoor unit then put them on pipe tube having completed burr removal not possible t...

Page 5: ...es according to color codes referring to the wiring diagram NOTE The power cord connected to unit should be selected according to the following national wiring regulations The supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord code designation 60245 IEC 57 H05RN F CAUTION Outdoor unit 1 Remove the tubing cover from the unit by loose...

Page 6: ...r 2 Connect a field supplied vinyl hose to the drain nipple A If the hose is too long and hangs down fix it carefully to prevent kinks The feature can be changed according to type of model Do not raise Water leakage Tip of drain hose dipped in water Water leakage Ditch Less than 50mm gap Accumulated drain water Air Waving Water leakage B A C 6 6 kW 2 5 3 5 5 0 kW Forming the Piping Form the piping...

Page 7: ...3 Reattach the cover by pushing it back into position If you press and hold the On Off button for 3 5 seconds instead of 6 seconds the unit will switch to the test operation In the test operation the unit blows out strong air for cooling for 18 minutes and then returns to the factory default settings This is performed when the unit is relocated or the refrigerant circuit is serviced Pump Down mean...

Page 8: ...lti model refer to Multi outdoor unit installation manual Capacity kW Pipe Size Standard Length m Max Length Ⓐ m Max Elevation Ⓑ m Additional Re frigerant g m GAS LIQUID mm inch mm inch 2 5 3 5 Ø9 52 3 8 Ø6 35 1 4 7 5 20 10 20 5 0 Ø12 7 1 2 Ø6 35 1 4 7 5 20 10 20 6 6 Ø15 88 5 8 Ø6 35 1 4 7 5 30 15 30 Capacity Mode Indoor temperature Outdoor temperature 2 5 3 5 kW Cooling 18 C 32 C 15 C 48 C Heatin...