System Set-Up
78
Air-to-Water Heat Pump
• Tank disinfection setting 1, 2
Disinfection operation is special DHW tank operation mode to kill and to prevent growth of viruses
inside the tank.
- Disinfection active : Selecting enable or disable of disinfection operation.
- Start date : Determining the date when the disinfection mode is running.
- Start time : Determining the time when the disinfection mode is running.
- Max temp. : Target temperature of disinfection mode.
- Duration time : Duration of disinfection mode.
Vales of Tank disinfection setting
• If Disinfection active is set as ’ Not use’, that is ‘disable disinfection mode’, Start date and Start
time is not used.
• When Disinfection active is set as ’Use’, that is ‘enable disinfection mode’, Start date is
displayed at the position of Disinfection active and Start time is displayed at the position of Start
date.
DHW heating should be enable
• If Disinfection active is set as ’ Not use’, that is ‘disable disinfection mode’, Start date and Start
time is not used.
• When Disinfection active is set as ’Use’, that is ‘enable disinfection mode’, Start date is
displayed at the position of Disinfection active and Start time is displayed at the position of Start
date.
Time
Start time
Max temp
Duration time
Water temperature
(Inside DHW)
Temperature profile
of Disinfection operation
1,MFL68681810,영영 2017. 7. 1. 영영 12:55 Page 78