12
REMOTE CONTROLLER INSTALLATION
ENGLISH
REMOTE CONTROLLER INSTALLATION
1
Please fix tightly using provided screw
after placing remote controller setup board
on the place where you like to setup.
- Please set it up not to bend because poor
setup could take place if setup board
bends.
Please set up remote controller board fit
to the reclamation box if there is a
reclamation box.
2
Can set up Wired remote controller cable
into three directions.
- Setup direction: the surface of wall
reclamation, upper, right
- If setting up remote controller cable into
upper and right side, please set up after
removing remote controller cable guide
groove.
* Remove guide groove with long nose.
①
Reclamation to the surface of the wall
②
Upper part guide groove
③
Right part guide groove
Since the room temperature sensor is in the
remote controller, the remote controller box
should be installed in a place away from direct
sunlight, high humidity and direct supply of
cold air to maintain proper space temperature.
Install the remote controller about 5 ft(1.5 m)
above the floor in an area with good air
circulation at an average temperature.
Do not install the remote controller where it
can be affected by:
- Drafts, or dead spots behind doors and in
corners.
- Hot or cold air from ducts.
- Radiant heat from sun or appliances.
- Concealed pipes and chimneys.
- Uncontrolled areas such as an outside wall
behind the remote controller.
- This remote controller is equipped with LCD.
display. For proper display of the remote
controller LCD's, the remote controller
should be installed properly as shown in
Fig.1.
(The standard height is 4~5 ft (1.2~1.5 m)
from floor level.)
1
2
3
2
3
5 ft
(1.5 m)
(Fig. 1)
Direct
Sun ray contact area
no
no
no
yes