background image

 

 

 

 

 

Indoor unit

R410A

5CSB0-02B (Replaces 5CSB0-02A)

P/No. : MFL67502506

Compact

Summary of Contents for ABNW18GBHC0

Page 1: ...Indoor unit R410A 5CSB0 02B Replaces 5CSB0 02A P No MFL67502506 Compact ...

Page 2: ...ouse which gives us an edge to LG to make better and latest technology products with best quality in optimized time These systems are equipped with inverter technology and R410A refrigerant which is perfect solution to various installation locations This Engineering product data book incorporates information about the product itself and installation designing for these systems The comprehensive st...

Page 3: ...Indoor unit Compact Compact General information 1 Model line up 2 External Appearance 3 Nomenclature Indoor unit ...

Page 4: ...hassis Name Capacity Index kW kBtu h 5 0 18 7 1 24 8 0 30 10 0 36 Ceiling Concealed Duct Middle Static Pressure BH Middle Static Pressure 2 M1 M2 Ceiling Concealed Duct Middle static pressure ABNW18GBHC0 UB18C NH0 ABNW24GBHC0 UB24C NH0 Ceiling Concealed Duct Middle static pressure 2 ABNW30GM1A0 UM30 N14 ABNW36GM2A0 UM36 N24 ...

Page 5: ...ss 18 30 000 Btu h Class 30 Model type W DC Inverter Heat pump A N Indoor units using R410A Indicates Product type B Ceiling Concealed Duct ABN W G 30 1 M A 0 18 000 Btu h Class 18 30 000 Btu h Class 30 Serial number Indoor Unit Outdoor Units N Indoor Unit U Outdoor Unit C Compact Nominal Capacity Ex Product type B M Ceiling Concealed Duct Connectable Outdoor unit type U Indoor units only for Sing...

Page 6: ...ing concealed duct Middle static pressure 1 List of functions 2 Specifications 3 Dimensions 4 Piping diagrams 5 Wiring Diagrams 6 External pressure setting for 7 Sound levels 8 Controller 9 Installation Indoor unit ...

Page 7: ...et Airflow direction control left right Airflow direction control up down Auto swing left right Auto swing up down Airflow steps fan cool heat Chaos wind auto wind Jet cool heat Swirl wind Triple filter Deodorizing Plasma air purifier Allergy Safe filter Long life prefilter washable anti fungus Drain pump E S P control Electric heater High ceiling operation Auto Elevation Grille Hot start Self dia...

Page 8: ...Pressure Pa mmAq Fan Motor Type Output W x No Dehumidification Rate l h pts h Sound Pressure Level H M L dB A Sound Power Level Max dB A Piping Connections Liquid mm inch Gas mm inch Drain O D I D mm Safety Devices Power and Communication Cable included Earth No x mm2 AWG 220 240 1 50 220 240 1 50 882 260 450 882 260 450 34 23 32 x 10 1 4 x 17 23 32 34 23 32 x 10 1 4 x 17 23 32 25 3 55 7 26 1 57 5...

Page 9: ...t box 2 Unit shall be grounded in accordance with the local regulations or applicable national codes 3 The Unit is powered from the outdoor unit Therefore power cable should be connected with the outdoor unit 140 29 70 260 87 750 30 47 355 450 219 932 133 355 450 114 224 6 0 R 3 7 5 47 24 49 21 882 158 260 65 108 64 243 212 243 119 75 115 745 20 175 3 2 5 1 4 6 119 428 106 127 122 50 100 165 100 4...

Page 10: ...gerant pipe connection port diameters Model Gas Liquid Unit mm Ø12 7 Ø15 88 Ø6 35 Ø9 52 ABNW18GBHC0 UB18C NH0 ABNW24GBHC0 UB24C NH0 Description PCB Connector Thermistor for suction air temperature CN ROOM Thermistor for evaporator inlet temperature CN PIPE IN Thermistor for evaporator outlet temperature CN PIPE OUT 4 _ Ceiling concealed duct Middle static pressure Indoor unit Compact 4 Piping diag...

Page 11: ...Indoor unit Compact 5 Wiring diagrams Ceiling concealed duct Middle static pressure _ 5 Indoor Units Models ABNW18GBHC0 UB18C NH0 ABNW24GBHC0 UB24C NH0 ...

Page 12: ...n F H Maximum E S P setting Fan speed doesn t vary according to the opening closing of dampers 3 Position V L Minimum E S P setting Fan speed is varied according to the state of dampers by micom 3 Move the slide switch to set position 4 Close the rear cover and check if it works normally TH R14H SW TH REMO MAIN 2TH OP7 R18H R17H OP6 LO STAND SW HIGH HI R03S C070 R04S R02S R01S OP3 OP2 OP1 R19H R11...

Page 13: ...n the remote controller TEMP FAN SPEED OPER MODE When pressing the button and button simultaneously for more than 3 seconds the system will be entered into the installer setting mode After entering into the installer setting mode select the E S P code value by pressing the button E S P code value 03 1 Select the desired air flow rate with the button Whenever pressing the button SLO LO MED HI POW w...

Page 14: ... 0 120 17 8 15 3 12 7 125 16 5 14 0 130 17 8 15 3 12 6 135 16 5 13 5 140 17 6 14 5 145 16 5 150 18 0 Unit CMM Unit CMM Table 2 Model Mode Set value External Static Pressure mmAq Pa CMM Lower Limit of External Static Pressure mmAq Pa Upper Limit of External Static Pressure mmAq Pa ABNW18GBHC0 UB18C NH0 High static Mode Factory Set Hl 6 59 13 5 2 5 25 8 78 Mid 12 0 Low 10 5 ABNW24GBHC0 UB24C NH0 Hig...

Page 15: ... 4 39 6 59 8 78 ABNW18GBHC0 UB18C NH0 ABNW24GBHC0 UB24C NH0 36 34 32 38 35 33 39 36 34 40 37 35 38 36 34 39 37 35 40 38 36 41 39 37 External Static Pressure 2 5 25 mmAq Pa Octave Band Center Frequency Hz Octave Band Sound Pressure Level 0 dB 20 μPa 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 Approximate Hearing Th...

Page 16: ...ter Frequency Hz 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 Approximate Hearing Threshold Octave Band Center Frequency Hz 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 Approximate Hearing Threshold ABNW18GBHC0 UB18C NH0 ABNW24GBHC0...

Page 17: ...fer the specifications 2 Reference acoustic intensity 0dB 10E 6μW m2 3 Sound level will vary depending on a range of factors such as the construction acoustic absorption coefficient of particular room in which the equipment in installed Octave Band Center Frequency Hz Sound Power Level 0dB 10E 6μW m 2 20 30 40 50 60 70 80 90 100 125 250 500 1000 2000 4000 8000 NR 30 NR 35 NR 40 NR 45 NR 50 NR 55 N...

Page 18: ...an be different from above contents depending upon model type When using simultaneous operation system whenever press remote controller button system will approximately operate after 1 2 minutes Each function will be shown on the display panel for three seconds or so when the power is applied at first h Some functions may not be operated and displayed depending on the product type TEMP FAN SPEED O...

Page 19: ...hether the following accessories are included with your unit 1 Standard accessories Please read the instruction sheets completely before installing the product When the power cord is damaged replacement work shall be performed by authorized personnel only Installation work must be performed in accordance with the national wiring standards by authorized personnel only Air filters Optional Air outle...

Page 20: ...s are fulfilled and also that meets with your customer s approval If supporting structural members are not strong enough to take the units weight the unit could fall out of place and cause serious injury Where sufficient clearance of maintenance and service can be ensured Where optimum air distribution can be ensured Where nothing blocks the air passage Where condensate can be properly drained Whe...

Page 21: ...rk the position for fixing bolts Drill the hole for set anchor on the face of ceiling Insert the set anchor and washer on the suspension bolts for locking the suspension bolts on the ceiling Mount the suspension bolts to the set anchor firmly Secure the installation plates on the suspension bolts adjust level roughly using nuts washers and spring washers Tighten the nut and bolt to prevent unit fr...

Page 22: ...ng Without drain pump Always lay the drain with downward inclination 1 50 to 1 100 Prevent any upward flow or reverse flow in any part 10mm or thicker formed thermal insulation shall always be provided for the drain pipe U trap is not required for low static model in which the external static pressure is below 50 pa 5mm Aq Liquid pipe Refrigerant pipe and thermal insulation Local supply Union for ...

Page 23: ...ls electric works must conform to local codes Use copper wire only Follow the WIRING DIAGRAM attached to the unit body to wire the outdoor unit indoor units and the remote controller All wiring must be performed by an authorized electri cian This system consists of multiple indoor units Mark each indoor unit as unit A unit B and be sure the terminal board wiring to the outdoor unit and indoor unit...

Page 24: ...er supply wiring to the terminal block for remote controller wiring A mistake of the sort could damage the entire system 6 Use only specified wire and tightly connect wires to terminals Be careful wires do not place exter nal stress on terminals Keep wiring in neat order and so as not to obstruct other equipment such as popping open the electric parts box cover Make sure the cover closes tight Inc...

Page 25: ...ng concealed duct Middle static pressure 2 1 List of functions 2 Specifications 3 Dimensions 4 Piping diagrams 5 Wiring Diagrams 6 External pressure setting for 7 Sound levels 8 Controller 9 Installation Indoor unit ...

Page 26: ...STA0 PZCWRCG3 Air supply outlet Airflow direction control left right Airflow direction control up down Auto swing left right Auto swing up down Airflow steps fan cool heat Chaos wind auto wind Jet cool heat Swirl wind Triple filter Deodorizing Plasma air purifier Allergy Safe filter Long life prefilter washable anti fungus Drain pump E S P control Electric heater High ceiling operation Auto Elevat...

Page 27: ...r Flow Rate High static Mode Factory Set H M L m3 min H M L ft3 min External Static Pressure Pa mmAq Fan Motor Type Output W x No Dehumidification Rate ℓ h pts h Sound Pressure Level H M L dB A Sound Power Level Max dB A Piping Connections Liquid mm inch Gas mm inch Drain O D I D mm inch Safety Devices Power and Communication Cable included Earth No x mm2 AWG 220 240 1 50 220 240 1 50 900 270 700 ...

Page 28: ...Ceiling concealed duct Middle static pressure 2 _ 3 3 Dimensions Indoor unit Compact Indoor Units M1 Chassis ABNW30GM1A0 UM30 N14 Supplied with product ...

Page 29: ...3 Dimensions Indoor unit Compact 4 _ Ceiling concealed duct Middle static pressure 2 Indoor Units M2 Chassis ABNW36GM2A0 UM36 N24 ...

Page 30: ... Thermistor for evaporator outlet temperature CN PIPE OUT Model Gas Liquid ABNW30GM1A0 UM30 N14 Ø15 88 Ø9 52 Sirocco Fan Heat exchanger Gas pipe connection port flare connection Liquid pipe connection port flare connection Cooling Heating M Thermistor for suction air temperature Thermistor for evaporator outlet temperature Thermistor for evaporator inlet temperature n Refrigerant pipe connection p...

Page 31: ...mistor for suction air temperature Thermistor for evaporator outlet temperature Thermistor for evaporator inlet temperature n Refrigerant pipe connection port diameters Unit mm Description PCB Connector Thermistor for suction air temperature CN ROOM Thermistor for evaporator inlet temperature CN PIPE IN Thermistor for evaporator outlet temperature CN PIPE OUT Models ABNW36GM2A0 UM36 N24 Model Gas ...

Page 32: ...Ceiling concealed duct Middle static pressure 2 _ 7 5 Wiring diagrams Indoor unit Compact Indoor Units Model ABNW30GM1A0 UM30 N14 ...

Page 33: ...5 Wiring diagrams Indoor unit Compact 8 _ Ceiling concealed duct Middle static pressure 2 Indoor Units Model ABNW36GM2A0 UM36 N24 ...

Page 34: ...system 1 Position V H Maximum E S P setting Fan speed is varied according to the state of dampers by micom 2 Position F H Maximum E S P setting Fan speed doesn t vary according to the opening closing of dampers 3 Position V L Minimum E S P setting Fan speed is varied according to the state of dampers by micom 3 Move the slide switch to set position 4 Close the rear cover and check if it works norm...

Page 35: ...etup mode by using button it indicates as the picture below 2 Select ESP fan step by pressing button 01 very low 02 low 03 medium 04 high 05 very high 3 Move to ESP value setting by pressing button It is 000 when delivering from the warehouse 4 Press button to setup ESP value It is possible to setup ESP value from 1 to 255 and 1 is the smallest and 255 is the biggest 5 If pressing button long for ...

Page 36: ...ltaneously for more than 3 seconds the system will be entered into the installer setting mode After entering into the installer setting mode select the static pressure step setting code value by pressing the button Static pressure step setting code value 32 1 Select the desired setting value with the temperature up s down t button 2 When pressing button currently established static pressure value ...

Page 37: ...13 9 105 22 0 19 8 17 7 15 3 13 0 110 23 3 21 1 19 1 16 8 14 6 115 24 6 22 4 20 5 18 3 16 3 14 2 120 25 9 23 7 21 8 19 7 17 9 15 9 13 3 125 25 1 23 2 21 2 19 6 17 5 15 2 14 6 130 24 6 22 7 21 2 19 2 17 1 16 3 135 24 2 22 9 20 9 19 0 18 1 140 24 5 22 6 20 9 19 9 Setting value Static Pressure mmAq Pa 4 39 6 59 8 78 10 98 12 118 14 137 15 147 85 24 9 90 27 6 22 7 95 30 4 25 7 20 7 100 33 1 28 7 24 0 ...

Page 38: ...9 88 10 98 11 108 12 118 13 127 15 147 Setting Value 32 01 32 02 32 03 32 04 32 05 32 06 32 07 32 08 32 09 32 10 32 11 ABNW36GM2A0 UM36 N24 LOW 24 0 88 91 95 100 101 108 113 115 118 118 118 MID 28 0 93 97 101 105 108 115 118 120 124 124 124 HIGH 32 0 101 105 109 112 115 119 123 126 128 128 128 Table 2 1 Be sure to set the value refering table 1 Unexpected set value will cause mal function 2 Table ...

Page 39: ...he center of the unit 2 Operating condition Power source 220 240V 50Hz 220V 60Hz Cooling Indoor temperature 27 C DB 19 C WB Outdoor temperature 35 C DB 24 C WB Heating Indoor temperature 20 C DB 15 C WB Outdoor temperature 7 C DB 6 C WB 3 Reference acoustic intensity 0dB 20μPa 4 Sound level will vary depending on a range of factors such as the construction acoustic absorption coefficient of partic...

Page 40: ...125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 Approximate Hearing Threshold ABNW30GM1A0 UM30 N14 ABNW36GM2A0 UM36 N24 n High Mid l Low Octave Band Center Frequency Hz Octave Band Sound Pressure Level 0 dB 20 μPa 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 App...

Page 41: ...3 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 Approximate Hearing Threshold n High Mid l Low External Static Pressure 15 147 mmAq Pa Octave Band Center Frequency Hz Octave Band Sound Pressure Level 0 dB 20 μPa 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 NC 15 NC 20 NC 25 NC 30 NC 35 NC 40 NC 45 NC 50 NC 55 NC 60 NC 65 App...

Page 42: ...ature 7 C DB 6 C WB External static pressure is according to Standard mode value Refer the specifications 2 Reference acoustic intensity 0dB 10E 6μW m2 3 Sound level will vary depending on a range of factors such as the construction acoustic absorption coefficient of particular room in which the equipment is installed External Static Pressure 2 5 25 mmAq Pa Octave Band Center Frequency Hz Sound Po...

Page 43: ...ately operate after 1 2 minutes 1 4 5 7 11 10 9 8 2 3 6 13 12 Please attach the inform label inside of the door Please choose proper language depend on your country 14 15 OPERATION INDICATION SCREEN SET TEMPERATURE Button FAN SPEED Button ON OFF Button OPRATION MODE SELECTION Button WIRELESS REMOTE CONTROLLER RECEIVER Some products don t receive the wireless signals AIR FLOW Button SUBFUNCTION But...

Page 44: ...n work must be performed in accordance with the national wiring standards Remote Controller Air inlet vents Air outlet vents 9 1 Accessories Check the following accessories are included with your unit 1 Standard accessories Name Quantity Shape for gas pipe for liquid pipe Clamp metal 2 EA Insulation for fitting 1 set Drain hose 1 EA Clamp Tie Wrap 8 EA Washer for hanging bracket 4 EA Other Screws ...

Page 45: ...e dimension H is necessary to get a slope to drain as figure The place shall easily connect with the outdoor unit The place where the unit is not affected by an electrical noise The place where air circulation in the room will be good There should not be any heat source or steam near the unit The servicing inspection hole in the ceiling should be as large as the product The selection of the servic...

Page 46: ...canvas between the unit and duct to absorb unnecessary vibration Install the unit leaning to a drainage hole side as a figure for easy water drainage 9 3 Ceiling dimension and hanging bolt location and service space CASE 1 C E G D F I A J B H Drain hole Unit mm Dimension A B C D E F G H I J Chassis name M1 933 4 971 6 619 2 700 30 270 15 2 858 201 4 900 M2 1283 4 1321 6 619 2 689 6 30 270 15 2 120...

Page 47: ...on of console Bolt A place where the unit will be leveled and that can sup port the weight of the unit A place where the unit can withstand its vibration A place where service can be easily performed Select and mark the position for fixing bolts Drill the hole for set anchor on the face of ceiling Insert the set anchor and washer onto the suspension bolts for locking the suspension bolts on the ce...

Page 48: ...t is operated for a long time in high humid atmosphere dew point temperature more than 23 73 F water drops are liable to fall In this case add heat insulation material according to the following procedure Heat insulation material Adiabatic glass wool with thick ness 10mm 13 32inch to 20mm 25 32inch Stick glass wool on all air conditioners that are located in ceiling atmosphere Make sure to insulat...

Page 49: ...hose with a downware inclination so water will drain out Wrong method With drain pump Possible drain head height is upto 700mm 27 9 16inch So the drain head should be below 700mm 27 9 16inch Keep the drain hose downward upto 1 50 1 100 inclina tion Prevent any upward flow or reverse flow in any part 5mm 3 16inch or thicker insulation should be provided for the drain pipe 27 9 16 inch 700mm 27 9 16...

Page 50: ...stem consists of multiple indoor units Mark each indoor unit as unit A unit B and be sure the terminal board wiring to the outdoor unit and ID unit are properly matched If wiring and piping between the outdoor unit and an indoor unit are mismatched the system may cause a malfunction A circuit breaker capable of shutting down the power supply to the entire system must be installed 2 Wiring connecti...

Page 51: ...lgeaircon com All rights reserved Printed in Korea The specifications designs and information in this brochure are subject to change without notice The air conditioners manufactured by LG have received ISO9001 certificate for quality assurance and ISO14001 certificate for environmental management system March 2016 ...

Reviews: