Installation
Installation Manual
9
ENGLISH
• Select and mark the position for fixing bolts.
• Drill the hole for set anchor on the face of ceil-
ing.
• Insert the set anchor and washer onto the sus-
pension bolts for locking the suspension bolts
on the ceiling.
• Mount the suspension bolts to the set anchor
firmly.
• Secure the installation plates onto the suspen-
sion bolts (adjust level roughly) using nuts,
washers and spring washers.
Connect the wires to the terminals on the control board individually according to the outdoor unit
connection.
• Ensure that the color of the wires of outdoor unit and the terminal No. are the same as those of in-
door unit respectively.
CAUTION : Tighten the nut and bolt to
prevent unit falling.
Terminal Block Indoor
Terminal Block Indoor
1(L)
2(N)
3
Outdoor unit
Indoor unit
Terminal Block outdoor
1(L)
2(N)
3
1 Set anchor
Old building
New building
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
Indoor Unit Installation
Wiring Connection
CAUTION : The Power cord connected to the unit should be selected according to the
following specifications. (Cable type CV approved by IEC 60502-1)
WARNING : Make sure that the screws of the terminal are free from looseness.
L1/L2/L3 Series
20mm
GN/YL
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
2