- 2 -
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7°C(80°F) DB / 19.4°C(67°F) WB
Outdoor 35°C(95°F) DB / 23.9°C(75°F) WB
- Heating Temperature : Indoor 21.1°C(70°F) DB / 15.6°C(60°F) WB
Outdoor 8.3°C(47°F) DB / 6.1°C(43°F) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
2. Wiring cable size must comply with the applicable local and national
code.
3. Due to our policy of innovation some specifications may be changed with-
out notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to
ambient conditions during operation.
* : This temperature (-20 ~ -10°C) can be operated only when Low Ambient
Kit is installed.
Outdoor unit
A4UW36GFA0
[LMU36CHV]
Testing Combination
AMNW09GDBL1 * 4EA
Capacity
Cooling
Min.~Rated~Max.
kW
9.37
Min.~Rated~Max.
Btu/h
32,000
Heating
Min.~Rated~Max.
kW
10.6
Min.~Rated~Max.
Btu/h
36,000
Power Input
Cooling Min.~Rated~Max.
kW
2.46
Heating Min.~Rated~Max.
kW
2.54
EER
Btu/Wh
13
SEER / HSPF
-
22.0/10.0
Power Supply
V , Ø , Hz
208/230, 1. 60
Running Current
Cooling Min.~Rated~Max.
A
11
Heating Min.~Rated~Max.
A
11.4
Starting Current
Cooling Max.
A
-
Heating Max.
A
-
Wiring Connections
Power Supply Cable (included Earth)
No. x mm
2
(AWG)
3C x 2.5 (12)
Power and Communication Cable
(included Earth)
Outdoor ~ BD unit
No. x mm
2
(AWG)
-
Combination
Sum of Indoor Units Capacity
kBtu/h
48
Number of Indoor Units
EA
4
Number of BD Units
EA
-
Casing Color
-
Warm Gray
Dimensions
W x H x D
mm
950 × 834 × 330
W x H x D
inch
37-13/32 x 32-27/32 x 13
Net Weight
kg (lbs)
62(136.7)
Compressor
Type
-
Twin Rotary
Model
Model x No.
GJT240MA x 1
Motor type
-
BLDC
Motor Output
W x No.
2,020 (at 60Hz) x 1
Refrigerant
Type
-
R410A
Precharged Amount
g (oz)
2,800 (98.8)
Chargeless-Pipe Length
m (ft)
30 (98.4)
Additional Charging Volume
g/m (oz/ft)
20 (0.22)
Control
-
Electronic Expansion Valve
Refrigerant Oil
Type
-
FVC68D
Charged volume
cc x No.
900 x 1
Heat Exchanger
(Row x Column x Fins per inch) x No.
-
(2 x 38 x 14) x 1
Fan
Type
-
Propeller
Air Flow Rate
m
3
/min x No. x No.
60 x 1
Fan Motor
Type
-
BLDC
Output
W x No.
124.2 x 1
Sound Pressure Level
Cooling Rated
dB(A)
52
Heating Rated
dB(A)
55
Sound Power Level
Cooling
Rated
dB(A)
62
Piping Connections
Liquid Outer
Dia.
mm(inch) x No.
Ø 6.35 (1/4) x 4
Gas Outer
Dia.
mm(inch) x No.
Ø 9.52 (3/8) x 4
Piping Length
Total Piping
Max.
m (ft)
75 (246)
Main Piping
Max.
m (ft)
-
Total Branch Piping
Max.
m (ft)
-
Each Branch Piping
Max.
m (ft)
25 (82.0)
Maximum Height Difference
Outdoor Unit ~ Indoor Unit
Max.
m (ft)
15 (49.2)
Indoor Unit ~ Indoor Unit
Max.
m (ft)
7.5 (24.6)
Operation Range
(Outdoor Temperature)
Cooling
Min. ~ Max.
℃ DB (℉ DB)
-18 (0.4)* ~ 48 (118.4)
Heating
Min. ~ Max.
℃ WB (℉ WB)
-20 (-4.0) ~ 18 (64.4)