Installation Manual
7
Installation of Indoor, Outdoor Unit
The wall you select should be strong and
solid enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a
concrete wall, use anchor bolts.
• Mount the installation plate horizontally by
aligning the centerline using a level.
2. Measure the wall and mark the centerline.
It is also important to use caution
concerning the location of the installation
plate-routing of the wiring to power outlets
is through the walls typically. Drilling the
hole through the wall for piping connections
must be done safely.
Chassis
Hook
Installation Plate
Type “A”
Chassis
Hook
Chassis
Hook
Installation Plate
Type “A”
Installation Plate
Type "A" Screws
Installation Plate
Chassis
Hook
Type "A" Screws
Ø70
Ø70
133
95
Right
rear
piping
Left
rear
piping
Installation Plate
Place a level on raised tab
Unit Outline
217
175
442
442
Ø70
Ø70
69
56
Right
rear
piping
Left
rear
piping
Installation Plate
Measuring Tape
Measuring Tape
Hanger
Place a level on raised tab
Unit Outline
207
105
460
570
<Type 1>
<Type 2>
<Type 3>
<Type 4>
<Type 2>
<Type 1>
<Type 3>
<Type 4>
Installation plate
Left rear piping
Right rear piping
Ø70
133
Ø70
100
Installation plate
Ø70
Ø70
110
90
110
70
Left rear piping
Right rear piping
Fixing Installation Plate
(Unit : mm)
Indoor Type
Capacity (kBtu/h)
Type
Wall mounted
9,12
3
18,24
4
ART COOL Mirror
9,12
1
18,24
2