background image

Owner's Manual 

23

ENGLISH

Maintenance and Service

Tripe Deodorizing Filter

Air filter

3

2

Filter

Filter

Grille, Case, and Remote Control

❏ 

Turn the system off before cleaning. To clean, wipe
with a soft, dry cloth. Do not use bleach or
abrasives.

Supply power must be disconnected before cleaning

the indoor unit.

Never use any of the followings:

• 

Water hotter than 40°C.
Could cause deformation and/or discoloration.

• 

Volatile substances
Could damage the surfaces of the air
conditioner.

1. Pull down the grille bottom, After lifting up the

filter tab a bit and take the filter out slowly
(Notice : Clean the filter after being stopped the
product)

2. Clean the filter with a vacuum or warm, soapy

water.

• If dirt is conspicuous, wash with a solution of

detergent in lukewarm water.

• If hot water (40°C or more) is used, it may be

deformed.

3. After washing with water, dry well in the shade.

4. Re-install the air filter.

NOTICE

Replacement of Purifying Filter(Optional)

• Recomended use period : About 2 years

1. Open front panel and remove air filters.

4. Reinsert air filter and close front panel.

2. Remove Triple deodorizing Filter.

3. Insert new Triple deodorizing Filter.

Artcool Type Indoor Unit

AIR FILTER

The air filters behind the
front grill should be
checked and cleaned
once every 2 weeks or
more often if neccessary.

Summary of Contents for A4UH306FA0

Page 1: ... set and retain it for future reference TYPE Multi The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment P NO 3828A20394A KZ O 02 0561 ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ...

Page 2: ...you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do not play...

Page 3: ...ic shock Do not handle the flamable gas or explosive materials near the product Do not install where flamable gas could leak Otherwise it may cause fire or failure of product Otherwise it may cause esplosion or fire Do not install the product on an defected installation stand Be cautious when unpack and install the product Otherwise It may cause injury or accident Sharp edges could cause injury Fo...

Page 4: ...ver the electric part Otherwise it may cause fire or electric shock Do not turn the breaker on off or connect disconnect the power supply plug during operation Otherwise it may cause fire or electric shock Do not open the suction inlet of the product during operation Otherwise it may cause electric shock or failure Do not touch the metal parts of the product when removing the air filter Otherwise ...

Page 5: ...not use wax tinner or a strong detergent etc Do not drink water drained from the product Otherwise it may change the apperance of the product Otherwise it may harm to your health Do not insert your hand or bars etc into the air inlet outlet Do not use the product at the closed space for a long time Otherwise it may cause personal injury Otherwise it may cause suffocation due to poor oxygen Do not ...

Page 6: ...eserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the po...

Page 7: ...pulling it according to the arrow direction Insert new batteries making sure that the and of battery are installed correctly Reattach the cover by sliding it back into position Use 2 AAA 1 5volt batteries Do not use rechargeable batteries NOTICE 3 2 1 The refering to the following picture fix the remote controller holder onto the wall using screws To operate the room air conditioner aim the Remote...

Page 8: ...ature For cooling dehumidification heating modes it display Destired temperature indicator Cooling 18 30 C AI Auto Operation Dehumidification 18 30 C Po Jet Cool Heating 16 30 C Lo Test Mode Desire temperature Icon Indoor temperature Icon Receives the signals from the remote controller Signal receiving sound two short beeps or one long beep Operation Indication Lamps Lights up during the system op...

Page 9: ...ring Timer operation Defrost Mode Plasma Lights up during Defrost Mode or Lights up during Plasma operation Hot Start operation Heat pump model only On Off For cooling dehumidification heating modes it display Destired temperature Cooling 18 30 C AI Auto Operation Dehumidification 18 30 C Po Jet Cool Heating 16 30 C Lo Test Mode Desire temperature indicator ...

Page 10: ...NG BUTTON Used to stop or start louver movement and set the desired up down airflow direction ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation TIME SETTING BUTTONS Used to adjust the time TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation SLEEP MODE AUTO BUTTON Used to set Sleep Mode Auto operation AIR CIRCU...

Page 11: ... direction of the arrow Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Cooling Operation Natural wind by the CHAOS logic For more fresh feeling press the Indoor Fan Speed Selector and set CHAOS mode In t...

Page 12: ...ontrols based on the actual room temperature If you want to change the set temperature press the Room Temperature Setting buttons The set temperature will be changed considering room temperature DURING AUTO OPERATION You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as desired manually switch to another mode The system will not automati...

Page 13: ...ehumidification mode on the operation selection button the A C starts to run the dehumidification function automatically setting the room temp and air volume to the best condition for dehumidification based on the sensed room temp In this case the setting temp is not displayed in the Remote Controller and you are not able to control the room temp either During the healthy dehumidification function...

Page 14: ...s shifted in the direction of the arrow NATURAL WIND BY THE CHAOS LOGIC For more fresh feeling than other fan speed press the Indoor Fan Speed Selector and set to CHAOS mode In this mode the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic 1 2 Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C i...

Page 15: ...nit will operate in high fan speed in cooling heating mode 1 2 3 Jet Cool function in heating mode is available on Artcool type only During the JET COOL function at any moment the A C starts to blow the cool heat air at extremely high speed for 30 60 minutes setting the room temp automatically to 18 C 30 C It is especially used to cool heat the room temperature in the shortest time In order to ret...

Page 16: ...when the button is pressed and stop when the button is pressed again Set the fan speed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA is available in Heating or any other operations 1 2 3 NANO PLASMA Purification Operation Optional If you press the PLASMA button NANO PLASMA air purifyi...

Page 17: ...ound Open the door of the Remote Controller and press the 2nd F button to operate functions printed in blue at bottom of buttons Check the indication of 2nd function on Remote Controller display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page 1 2 3 ...

Page 18: ...inutes and by 2 C in 1 hour for comfortable sleeping NOTICE 1 Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button 2 Press 2nd F button and check if 2nd F icon is on 3 Press the Time Setting buttons until the desired time is set 4 Press the Timer SET button Check the indi...

Page 19: ...ill close the air outlet vent of the system To adjust left right Horizontal Airflow direction Caution Ensure that the unit is turned off before adjusting the horizontal airflow direction control Carefully open vertical louver to allow access to the horizontal airflow direction Adjust the left right airflow direction by hand NOTICE Standard Artcool Deluxe Type Artcool Type The up down and right lef...

Page 20: ...lates the room air without cooling and heating for 14 minutes And then unit stops operating NOTE During Auto Clean function moistures left in indoor units after Cooling Operation or Healthy Dehumidification Operation can be removed During Auto Clean function only Start Stop button Plasma button and Auto Clean button are available Auto Clean Artcool Artcool Deluxe Artcool Mirror Type Only Display L...

Page 21: ...es on again after a power failure the unit operates automatically to the previous operating conditions So there is no need of activating this function by pressing any key or button In the initial mode the fan operates at a low speed and the compressor starts about 3 minutes later As the compressor starts the fan speed also resumes its previous setting mode Helpful information Fan speed and cooling...

Page 22: ...rd to remove the filter 2 Clean the filter with a vacuum cleaner or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Vertical louver Horizontal louver Air filters behind front panel Air outlet vent Air inlet vent Gasolin...

Page 23: ... and take the filter out slowly Notice Clean the filter after being stopped the product 2 Clean the filter with a vacuum or warm soapy water If dirt is conspicuous wash with a solution of detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter NOTICE Replacement of Purifying Filter Optional Recome...

Page 24: ...the neutral detergent for 1 2 hours and then raise them 4 Insert the Plasma Filter after perfectly drying in shade Now insert Air Filter and close the Front panel Completely by matching the hook Air Filter Air Filter Front Panel Hook Hook Hanger Air Filter Plasma Purifier Filter Front Panel Front panel Panel hook Artcool Deluxe Type Indoor Unit 1 Open the upside of Front Panel 2 Lift up the Front ...

Page 25: ...Water hotter than 40 C Could cause deformation and or discoloration Volatile substances Could damage the surfaces of the air conditioner Don t touch this nano PLASMA Filter within 10 seconds after opening the inlet grille it may cause an electric shock Cleaning of Purifying Filter Recomended use period About 3 months 1 Open the upside of Front panel 2 Put up the front panel The hook of panel comes...

Page 26: ... used it may be deformed 4 After washing with water dry well in the shade 5 Re install the air filter NANO PLASMA FILTER The NANO PLASMA filter behind the air filters should be checked and cleaned once in every 3 months or more often if necessary 1 After removing the air filters pull slightly forward to remove the NANO PLASMA filter 2 Remove dust with vacuum cleaner or air You should not try to wa...

Page 27: ... Refer to page 23 27 for cleaning filters Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows if possible to keep the cool air in the room Keep blinds or curtains closed Do not let direct sunshine enter the ro...

Page 28: ...cloth items in the room Check the drain hose is connected tight or if indoor unit is installed even This is the protector of the mechanism Wait about 3 minutes and operation will begin About 3 minutes delay is applied to protect compressor from frequenty on off Is the air filter dirty See air filter cleaning instructions Has the temperature been set correctly Are the indoor unit s air inlet or out...

Page 29: ......