INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
9
Fixing Installation Plate
The wall you select should be strong and solid
enough to prevent vibration
1
Mount the installation plate on the wall
with type "A" screws. If mounting the unit
on a concrete wall, use anchor bolts.
- Mount the installation plate horizontally
by aligning the centerline using a level.
<Type 1>
<Type 2>
2
Measure the wall and mark the centerline.
It is also important to use caution concern-
ing the location of the installation plate-
routing of the wiring to power outlets is
through the walls typically. Drilling the hole
through the wall for piping connections
must be done safely.
<Type 1>
<Type 2>
Installation Plate
Chassis
Type "A" Screws
Installation Plate
Chassis
Hook
Type "A" Screws
Indoor Type
Capacity
(kBtu/h)
Type
Wall mounted
/ART COOL
Mirror
9 / 12
1
18 / 24
2
Ø70
Ø70
133
95
Right rear piping
Left rear piping
Installation Plate
Place a level on raised tab
Unit Outline
217
175
(Unit : mm)
442
442
Ø65
Ø65
69
56
Right rear
piping
Left rear
piping
Installation Plate
Measuring Tape
Measuring Tape
Hanger
Place a level on raised tab
Unit Outline
207
105
(Unit : mm)
460
570
Summary of Contents for A3UQ24GFD0