- 63 -
3) Electrical Wiring
Power cord
Terminal on the OUTDOOR UNIT
3
1(L) 2(N)
OUTDOOR UNIT
1(L) 2(N)
Terminal on the INDOOR UNIT
D-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
C-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
B-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
A-UNIT
1(L) 2(N)
3
3
2(N)
3
3
1(L)
Power cord
Terminal on the OUTDOOR UNIT
3
1(L) 2(N)
OUTDOOR UNIT
1(L) 2(N)
Terminal on the INDOOR UNIT
A-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
B-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
C-UNIT
1(L) 2(N)
3
3
2(N)
3
3
1(L)
Power cord
Terminal on the OUTDOOR UNIT
3
1(L) 2(N)
OUTDOOR UNIT
1(L) 2(N)
Terminal on the INDOOR UNIT
A-UNIT
1(L) 2(N)
3
Terminal on the INDOOR UNIT
B-UNIT
1(L) 2(N)
3
3
2(N)
3
3
1(L)
Power cord
Connecting
cable
Cover control
Terminal block
Outdoor unit
Over 5mm
Holder for
power supply
cord
1. Remove the cover control from the unit by loosen-
ing the screw.
Connect the wires to the terminals on the control
board individually as the following.
2. Secure the cable onto the control board with the
holder (clamper).
3. Refix the cover control to the original position with
the screw.
4. Use a recongnized circuit breaker between the
power source and the unit. A disconnection device
to adequately disconnect all supply lines must be
fitted.
CAUTION
ø
8.5mm
GN/YL
20mm
ø
7.5mm
GN/YL
20mm
The power cord connected to the outdoor unit
should be complied with the following specifica-
tions (Rubber insulation, type H05RN-F
approved by HAR or SAA).
The connecting cable connected to the indoor
and outdoor unit should be complied with the
following specifications (Rubber insulation, type
H07RN-F approved by HAR or SAA).
NORMAL CROSS-
SECTIONAL AREA
0.75mm
2
NORMAL CROSS-
SECTIONAL AREA
3.5mm
2
Air
Conditioner
Air
Conditioner
Circuit Breaker
Use a 20A circuit
breaker or time
delay fuse.
(21K)
Main power source
Main power source
Circuit Breaker
Use a 25A circuit
breaker or time
delay fuse.
(30K)
CAUTION
If a power plug is not to be used, provide a circuit breaker between power source and the unit as shown below.
Summary of Contents for A2UN186FA0
Page 104: ... 104 Electronic Control Device 1 Room Type Indoor Unit MAIN P C B DC ASM MAIN P C B AC ASM ...
Page 105: ... 105 2 Cassette Type Indoor Unit MAIN P C B DC ASM ...
Page 106: ... 106 3 Art Cool Type Indoor Unit TOP VIEW BOTTOM VIEW ...
Page 107: ... 107 4 Convertible Type Indoor Unit ...
Page 109: ... 109 6 SUB P W B ASSEMBLY Art Cool Type Indoor Unit TOP VIEW BOTTOM VIEW ...
Page 110: ... 110 7 Outdoor Unit MAIN P C B ASM V P U N W ...
Page 111: ... 111 Schematic Diagram 1 Room Type Indoor Unit ...
Page 113: ... 113 3 Art Cool Type Indoor Unit ...
Page 114: ... 114 4 Convertible Type Indoor Unit RY 4WAY RY OUTFAN ...
Page 132: ...P No 3828A20097N August 2003 Printed in Korea ...