Standard Repair Process Detail Technical Manual
Remote control operation checking method
D. Function error
Established
date
Revised
date
Error
symptom
Content
A23
Checking order
1. Check BT/Wifi cable condition between BT/Wifi assy & Main board.( Check
①
and
②
)
2. Check the 3.5V on the terminal 22. (
③
)
Checking order to check motion remote/wifi
① Wifi & BT Front
Wifi & BT Rear
A23
Pin
Pin name
1
VCC
2
USB_DM
3
USB_DP
4
GND
5
WOL/WIFI_ON
6
VCC
7
WIFI_Suspend/Resume
8
GND
9
Combo_Reset
10
BT_WAKEUP_HOST
11
GND
12
VCC
13
14
15
16
EYE_SDA
17
EYE_SCL
18
GND
19
IR
20
LED_R
21
GND
22
VCC
23
KEY2
24
MIC_DATA
25
MIC_CLK
③
* Depending on models
< Below 75inch_ NANO7*,UP8*,UP77 >
< Below 75inch_UP75/71 >
②