- 11 -
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
O
Detail EDID Options are below (
ⓐ
,
ⓑ
,
ⓒ
,
ⓓ
,
ⓔ
)
ⓐ
Product ID
ⓑ
Serial No
=> Controlled on production line
ⓒ
Month, Year
=> Controlled on production line:
ex) Monthly: ‘11’ -> ‘0B’
Year: ‘2007’ -> ‘11’
ⓓ
Model Name(Hex)
ⓔ
Checksum
=> Changeable by total EDID data
1) Analog(128Byte)
2) HDMI 1/2/3(256Byte)
7-5. Preparation for Adjustment
(1) As above Fig. 3, Connect the Set, EDID Download Jig,,
PC & Cable
(2) Turn on the PC & EDID Download Jig. And Execute the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option
Repeat Number : 5
Device Address : A0
PageByte : 8
(4) Power on the Set
1) Sequence of Adjustment
1. DDC data of Analog-RGB
(1) Init the data
(2) Load the EDID data.(Open File).
(3) Set the S/W as below.