THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FILRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFATURES SPECFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
0 . 1 u F
C1005
UART_RX
0 . 1 u F
C1002
0 . 3 3 u F
C1000
0 . 1 u F
C1003
+3.5V_ST
0 . 1 u F
C1004
0 . 1 u F
C1001
SPG09-DB-009
JK1000
1
2
3
4
5
6
7
8
9
10
EAN41348201
MAX3232CDR
IC1000
3
C1-
2
V+
4
C2+
1
C1+
6
V-
5
C2-
7
DOUT2
8
RIN2
9
ROUT2
10
DIN2
11
DIN1
12
ROUT1
13
RIN1
14
DOUT1
15
GND
16
VCC
IR_OUT_RS232C
+3.5V_ST
1K
R1004
UART_TX
1SS355
90V
D1002
4.7K
R1005
4.7K
R1006
+3.5V_ST
RS232C_9PIN
RS232C
EMEA INTERACTIVE
LP63xH-ZA
2 0 1 2 . 1 1 . 0 5
1 0
Copyright © 2013 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
LGE Internal Use Only
Summary of Contents for 60LN549E
Page 67: ......