THERMAL
THERMAL
THERMAL
THE SYMBOL MARK OF THIS SCHEMETIC DIAGRAM INCORPORATES
SPECIAL FEATURES IMPORTANT FOR PROTECTION FROM X-RADIATION.
FIRE AND ELECTRICAL SHOCK HAZARDS, WHEN SERVICING IF IS
ESSENTIAL THAT ONLY MANUFACTURES SPECIFIED PARTS BE USED FOR
THE CRITICAL COMPONENTS IN THE SYMBOL MARK OF THE SCHEMETIC.
C13401
22uF
C13405
0.1uF
16V
+1.5V_U_DDR
POWER_ON/OFF_1
R
1
3
4
0
6
9
1
K
1
/
1
6
W
1
%
C13408
10uF
16V
C13449
22uF
10V
R13410
20K
1/16W
1%
C13446
2200pF
50V
C13444
100pF
50V
C13447
0.1uF
16V
R13409
5.1K
1/16W
1%
D13400
30V
OPT
R13408
4.87K
1/16W
1%
R13403
4.7
IC13402
TPS53513RVER
1
RF
3
EN
7
SW_2
9
SW_4
10
PGND_1
11
PGND_2
12
PGND_3
13
PGND_4
14
PGND_5
15
VIN_1
16
VIN_2
17
VIN_3
18
NC_2
19
VDD
20
VREG
21
MODE
22
GND
23
FB
24
VO
25
TRIP
26
NC_3
27
GND1
28
GND2
5
NC_1
8
SW_3
6
SW_1
4
VBST
2
PGOOD
29
[EP]
C13403
1000pF
50V
L13411
BLM18PG121SN1D
R13400
2K
1/16W
5%
C13443
10uF
16V
R13423
22K
1%
1
/
1
6
W
C13448
22uF
10V
R13422
3.6K
1%
C13410
0.1uF
C13411
22uF
C13400
22uF
+12V
C13407
1uF
10V
R13407
39K
1/16W
5%
R13404
10K
VDDC
R13424
10K
ZD13400
2.5V
R13421
18K
1%
C13445
1uF
10V
L13402
C13406
2200pF
50V
C13404
470pF
50V
C13409
10uF
16V
C13402
0.1uF
16V
R13402
3.3
1/10W
5%
+12V
R
1
3
4
0
5
2
7
K
1
/
1
6
W
1
%
ZD13401
2.5V
OPT
R13425
10K
+3.3V_U_NORMAL
R13426
10K
OPT
R13401
0
C13413
0.1uF
C13417
0.1uF
16V
C13416
2200pF
50V
+12V
L13401
BLM18PG121SN1D
R13415
10K
C13418
22uF
10V
C13415
1uF
10V
C13414
100pF
50V
R13414
22K
1%
1
/
1
6
W
C13419
22uF
10V
C13412
10uF
16V
+3.3V_U_NORMAL
R13412
68K
1%
R13413
6.8K
1%
+3.3V_NORMAL
D13401
5V
TVS_SEMTECH(MULTI)
L13403
1.0uH
L13412
2.2uH
VLS5045EXT-2R2N
L13404
2.2uH
VLS5045EXT-2R2N
IC13403
BD9D321EFJ
3
VREG
2
FB
4
SS
1
EN
5
GND
6
SW
7
BOOT
8
VIN
9
[EP]
IC13401
BD9D321EFJ
3
VREG
2
FB
4
SS
1
EN
5
GND
6
SW
7
BOOT
8
VIN
9
[EP]
D13401-*1
TVS_KEC(MULTI)
R13411
240
1/16W
1%
+1.5V URSA DDR
3A
+1.15V URSA9 Core
Vout=0.6*(1+R1/R2)
Vout=0.765*(1+R1/R2)=1.516V
8A
R1
R1
R2
R2
MAX 4.7A
2014.04.24
URSA_DCDC
M1A_URSA9_UD
134
R1
R2
3A
+3.3V URSA
Copyright ⓒ 2015 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Summary of Contents for 49UF6700